Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Radon mitigation with pressure-controlled mechanical ventilation
AbstractEffective ventilation and positive or low negative pressure indoors are suggested to achieve low indoor radon levels. The aim of this study was to develop and to test equioment which makes it possible to achieve simultaneously effective ventilation and minimum indoor-outdoor pressure difference. The unit included mechanical supply and exhaust air fans, a heat-exchabger and a pressure control unit in direct digital control (DDC), which continuously adjusted air flows based on the pressure difference transmitter information. Indoor radon level decreased from after two weeks of the equipment's installation during winter conditions. The arithmetic week average of indoor radon level was 135 Bq/m3 from May to August. When the set value of pressure difference adjustment was slightly positive (0.2 Pa) and in-out temperature difference was small in August, the minimum level () was obtained.
Radon mitigation with pressure-controlled mechanical ventilation
AbstractEffective ventilation and positive or low negative pressure indoors are suggested to achieve low indoor radon levels. The aim of this study was to develop and to test equioment which makes it possible to achieve simultaneously effective ventilation and minimum indoor-outdoor pressure difference. The unit included mechanical supply and exhaust air fans, a heat-exchabger and a pressure control unit in direct digital control (DDC), which continuously adjusted air flows based on the pressure difference transmitter information. Indoor radon level decreased from after two weeks of the equipment's installation during winter conditions. The arithmetic week average of indoor radon level was 135 Bq/m3 from May to August. When the set value of pressure difference adjustment was slightly positive (0.2 Pa) and in-out temperature difference was small in August, the minimum level () was obtained.
Radon mitigation with pressure-controlled mechanical ventilation
Kokotti, Helmi (Autor:in) / Keskikuru, Timo (Autor:in) / Kalliokoski, Pentti (Autor:in)
Building and Environment ; 29 ; 387-392
01.01.1994
6 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Radon mitigation with pressure-controlled mechanical ventilation
British Library Online Contents | 1994
|Radon mitigation with pressure-controlled mechanical ventilation
Online Contents | 1994
|Radon Mitigation with Controlled Mechanical Ventilation
British Library Conference Proceedings | 1994
|Comparison of natural and forced ventilation for radon mitigation in houses
Online Contents | 1996
|