Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo
AbstractThe impact-echo method has been successfully applied to identify defects inside concrete. In addition, to detect ungrouted tendon ducts in a large concrete slab, a scanning impact-echo technique is developed. However, since resonant frequencies in the spectrum responsible for the travel paths via defects are only taken into account, the method could lead to erroneous results due to complicated spectra obtained in the tests. Consequently, Stack Imaging of spectral amplitudes Based on Impact-Echo (SIBIE) procedure has been developed to improve the data interpretation.Conventionally, SIBIE is applied to a single measurement data and a point information of defects is obtained at the area, where the impact test is performed. In this study, SIBIE is applied to scanning impact-echo data. Locations of ungrouted tendon ducts embedded in a large concrete specimen are investigated. In order to visualize the whole cross-section tested, the SIBIE analysis is modified, introducing an elliptical integration mode. It is demonstrated that ungrouted tendon ducts are successfully located by the modified SIBIE analysis, whereas results of the conventional B-scan analysis are not so good as the modified SIBIE analysis.
Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo
AbstractThe impact-echo method has been successfully applied to identify defects inside concrete. In addition, to detect ungrouted tendon ducts in a large concrete slab, a scanning impact-echo technique is developed. However, since resonant frequencies in the spectrum responsible for the travel paths via defects are only taken into account, the method could lead to erroneous results due to complicated spectra obtained in the tests. Consequently, Stack Imaging of spectral amplitudes Based on Impact-Echo (SIBIE) procedure has been developed to improve the data interpretation.Conventionally, SIBIE is applied to a single measurement data and a point information of defects is obtained at the area, where the impact test is performed. In this study, SIBIE is applied to scanning impact-echo data. Locations of ungrouted tendon ducts embedded in a large concrete specimen are investigated. In order to visualize the whole cross-section tested, the SIBIE analysis is modified, introducing an elliptical integration mode. It is demonstrated that ungrouted tendon ducts are successfully located by the modified SIBIE analysis, whereas results of the conventional B-scan analysis are not so good as the modified SIBIE analysis.
Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo
Alver, Ninel (Autor:in) / Wiggenhauser, Herbert (Autor:in)
Construction and Building Materials ; 24 ; 2388-2392
01.01.2010
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo
British Library Online Contents | 2010
|Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo
Online Contents | 2010
|Imaging of ungrouted tendon ducts in prestressed concrete by improved SIBIE
Tema Archiv | 2007
|Identification of ungrouted tendon duct in prestressed concrete by SIBIE
Tema Archiv | 2009
|