Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Mitigation measures for pile groups behind quay walls subjected to lateral flow of liquefied soil: Shake table model tests
AbstractThis paper presents experimental results of a series of 1g shake table tests on mitigation measures for a model consisting of a 3×3 pile group and a sheet-pile quay wall in which the pile group was subjected to liquefaction-induced lateral spreading. First, general observations associated with the mechanism of lateral spreading and pile response are presented based on tests without remedial measures, followed by in depth discussions. Second, three remedial techniques were deployed to provide an adequate seismic performance of the pile group and the quay wall: (i) mitigating sheet pile of floating type, (ii) mitigating sheet pile of fixed end type, and (iii) anchoring the quay wall to a new pile row. The main objective of these mitigation methods was to restrict ground distortion behind the quay wall, enhancing seismic response of pile group and quay wall. This mitigation philosophy was decided based on the outcome of the first part, which consisted of a series of tests without mitigation measures. In addition, it should be noted that the proposed countermeasures were selected to be applicable for existing vulnerable pile groups, which are at risk of liquefaction and lateral spreading. Results of different mitigation tests are comparatively examined using a parameter called reduction factor, and the effectiveness of each countermeasure is discussed in detail. The results demonstrate that by applying the proposed mitigation measures the seismic performance of both pile group and quay wall can be improved, as a result of reduction in soil displacement and velocity of soil flow.
Mitigation measures for pile groups behind quay walls subjected to lateral flow of liquefied soil: Shake table model tests
AbstractThis paper presents experimental results of a series of 1g shake table tests on mitigation measures for a model consisting of a 3×3 pile group and a sheet-pile quay wall in which the pile group was subjected to liquefaction-induced lateral spreading. First, general observations associated with the mechanism of lateral spreading and pile response are presented based on tests without remedial measures, followed by in depth discussions. Second, three remedial techniques were deployed to provide an adequate seismic performance of the pile group and the quay wall: (i) mitigating sheet pile of floating type, (ii) mitigating sheet pile of fixed end type, and (iii) anchoring the quay wall to a new pile row. The main objective of these mitigation methods was to restrict ground distortion behind the quay wall, enhancing seismic response of pile group and quay wall. This mitigation philosophy was decided based on the outcome of the first part, which consisted of a series of tests without mitigation measures. In addition, it should be noted that the proposed countermeasures were selected to be applicable for existing vulnerable pile groups, which are at risk of liquefaction and lateral spreading. Results of different mitigation tests are comparatively examined using a parameter called reduction factor, and the effectiveness of each countermeasure is discussed in detail. The results demonstrate that by applying the proposed mitigation measures the seismic performance of both pile group and quay wall can be improved, as a result of reduction in soil displacement and velocity of soil flow.
Mitigation measures for pile groups behind quay walls subjected to lateral flow of liquefied soil: Shake table model tests
Motamed, Ramin (Autor:in) / Towhata, Ikuo (Autor:in)
Soil Dynamics and Earthquake Engineering ; 30 ; 1043-1060
17.04.2010
18 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2010
|Shaking Table Model Tests on Pile Groups behind Quay Walls Subjected to Lateral Spreading
Online Contents | 2010
|Shaking Table Model Tests on Pile Groups behind Quay Walls Subjected to Lateral Spreading
British Library Online Contents | 2010
|Shake table tests for caisson-type quay walls retrofitted by geogrids
Tema Archiv | 2006
|