Comparison of environmental impacts of two residential heating systems
AbstractThis paper presents a comparison of environmental impacts of two residential heating systems, a hot water heating (HWH) system with mechanical ventilation and a forced air heating (FAH) system. These two systems are designed for a house recently built near Montreal, Canada. The comparison is made with respect to the life-cycle energy use, the life-cycle greenhouse gas (GHG) emissions, the expanded cumulative exergy consumption (ECExC), the energy and exergy efficiencies, and the life-cycle cost. The results indicate that the heating systems cause marginal impacts compared with the entire house in the pre-operating phase. In the operating phase, on the other hand, they cause significant environmental impacts. The HWH systems with a heat recovery ventilator (HRV) using either electricity or natural gas have the lowest life-cycle energy use and lowest ECExC. The HWH and FAH systems using electricity as energy source have the lowest GHG emissions. Finally, the FAH systems have, on the average, a lower life-cycle cost than the HWH systems.
Comparison of environmental impacts of two residential heating systems
AbstractThis paper presents a comparison of environmental impacts of two residential heating systems, a hot water heating (HWH) system with mechanical ventilation and a forced air heating (FAH) system. These two systems are designed for a house recently built near Montreal, Canada. The comparison is made with respect to the life-cycle energy use, the life-cycle greenhouse gas (GHG) emissions, the expanded cumulative exergy consumption (ECExC), the energy and exergy efficiencies, and the life-cycle cost. The results indicate that the heating systems cause marginal impacts compared with the entire house in the pre-operating phase. In the operating phase, on the other hand, they cause significant environmental impacts. The HWH systems with a heat recovery ventilator (HRV) using either electricity or natural gas have the lowest life-cycle energy use and lowest ECExC. The HWH and FAH systems using electricity as energy source have the lowest GHG emissions. Finally, the FAH systems have, on the average, a lower life-cycle cost than the HWH systems.
Comparison of environmental impacts of two residential heating systems
Yang, Lijun (Autor:in) / Zmeureanu, Radu (Autor:in) / Rivard, Hugues (Autor:in)
Building and Environment ; 43 ; 1072-1081
02.02.2007
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Comparison of environmental impacts of two residential heating systems
Online Contents | 2008
|Comparison of environmental impacts of two residential heating systems
British Library Online Contents | 2008
|A Comparison of Residential Subdivision Site Designs for Environmental Impacts
British Library Conference Proceedings | 2007
|Impacts of vegetation on residential heating and cooling
Elsevier | 1987
|Impacts of vegetation on residential heating and cooling
Elsevier | 1988
|