Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Microcones configured with full-bridge circuits
Abstract Small-diameter microcones have been widely used for the characterisation of soil properties in the field and in the calibration chamber because the smaller probe may require a smaller penetrometer capacity and a smaller calibration chamber. As the cone size decreases, the area required for the installation of the strain gauges also decreases, and thus, the half-bridge circuit has been generally adopted. The objective of this study is the development and application of a microcone configured with a full-bridge circuit instead of the half-bridge circuit for the measurement of the cone tip resistance and sleeve friction. The diameter of the microcone is designed to be D=15mm, and thus, the projected area is 1.76cm2. The full-bridge circuit in the microcone is configured by extending the rod behind the connection part for the installation of four strain gauges. Two strain gauges are installed in the loading part, and two strain gauges are installed in the extended rod. In addition, the half-bridge circuit is also used for comparison of the cone tip resistance and sleeve friction in both circuits. The advantages of the microcone with the extended rod are verified through a theoretical background study and through experimental studies of various parameters, including temperature calibration, stress calibration, and densification monitoring. The test results show that the extended rod-type microcone with a full-bridge is less affected by environmental effects and produces better linearity between the output voltage and the stress. In addition, the full-bridge circuit yields more reasonable and reliable cone tip resistance and sleeve friction values than the half-bridge circuit. This study demonstrates that the extended rod-type microcone may be an alternative choice for the configuration of the full-bridge for better resistance measurements.
Highlights ► Small-diameter microcones have been widely used. ► The half-bridge circuit has been generally adopted. ► The full-bridge circuit in the microcone is configured by extending the rod. ► Extended rod-type microcone is less affected by environmental effects.
Microcones configured with full-bridge circuits
Abstract Small-diameter microcones have been widely used for the characterisation of soil properties in the field and in the calibration chamber because the smaller probe may require a smaller penetrometer capacity and a smaller calibration chamber. As the cone size decreases, the area required for the installation of the strain gauges also decreases, and thus, the half-bridge circuit has been generally adopted. The objective of this study is the development and application of a microcone configured with a full-bridge circuit instead of the half-bridge circuit for the measurement of the cone tip resistance and sleeve friction. The diameter of the microcone is designed to be D=15mm, and thus, the projected area is 1.76cm2. The full-bridge circuit in the microcone is configured by extending the rod behind the connection part for the installation of four strain gauges. Two strain gauges are installed in the loading part, and two strain gauges are installed in the extended rod. In addition, the half-bridge circuit is also used for comparison of the cone tip resistance and sleeve friction in both circuits. The advantages of the microcone with the extended rod are verified through a theoretical background study and through experimental studies of various parameters, including temperature calibration, stress calibration, and densification monitoring. The test results show that the extended rod-type microcone with a full-bridge is less affected by environmental effects and produces better linearity between the output voltage and the stress. In addition, the full-bridge circuit yields more reasonable and reliable cone tip resistance and sleeve friction values than the half-bridge circuit. This study demonstrates that the extended rod-type microcone may be an alternative choice for the configuration of the full-bridge for better resistance measurements.
Highlights ► Small-diameter microcones have been widely used. ► The half-bridge circuit has been generally adopted. ► The full-bridge circuit in the microcone is configured by extending the rod. ► Extended rod-type microcone is less affected by environmental effects.
Microcones configured with full-bridge circuits
Yoon, Hyung-Koo (Autor:in) / Lee, Jong-Sub (Autor:in)
Soil Dynamics and Earthquake Engineering ; 41 ; 119-127
16.05.2012
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Microcones configured with full-bridge circuits
British Library Online Contents | 2012
|Microcones configured with full-bridge circuits
Online Contents | 2012
|Self-assembled Nb2O5 microcones with tailored crystallinity
British Library Online Contents | 2006
|Preparation and photoelectrochemical properties of KTa5O13 microcones
British Library Online Contents | 2010
|Formation of well dispersed TiO2 microcones; the 20% surface occupation
British Library Online Contents | 2018
|