Obtaining the heat loss coefficient of a dwelling using its heating system (integrated coheating)
Highlights Whole house heat loss test method using dwelling’s own heating system is proposed. HLC estimates from integrated coheating are compared with electric coheating. Good agreement between the HLC estimates obtained using each method. Integrated HLC estimate could be more indicative of how a dwelling performs in-use. Efficiency of the dwelling’s heating system can also be obtained using test method.
Abstract This paper presents the methodology, along with some of the initial findings and observations from tests performed on two dwellings, of differing construction and form, in which a coheating test was performed using the dwelling’s central heating system; this method is referred to as integrated coheating. Data obtained during the integrated coheating tests using a dwelling’s heating system have been compared with data obtained during electric coheating of the same dwelling. In one instance, integrated coheating test data from one dwelling was compared to a similar adjoining control dwelling that was simultaneously subject to an electric coheating test. The results show a good agreement between the heat loss coefficients (HLC) obtained using a dwelling’s own heating system and those obtained through electrical coheating. Initial analysis suggests the HLC estimate obtained from integrated coheating is likely to be more representative of how a dwelling performs in-use. The findings question the appropriateness of comparing current steady-state HLC predictions to those derived from in-use monitoring data. Integrated coheating has the potential to provide a more cost-effective and informative indication of whole house heat loss than electric coheating, as it enables in situ quantification of both fabric and heating system performance.
Obtaining the heat loss coefficient of a dwelling using its heating system (integrated coheating)
Highlights Whole house heat loss test method using dwelling’s own heating system is proposed. HLC estimates from integrated coheating are compared with electric coheating. Good agreement between the HLC estimates obtained using each method. Integrated HLC estimate could be more indicative of how a dwelling performs in-use. Efficiency of the dwelling’s heating system can also be obtained using test method.
Abstract This paper presents the methodology, along with some of the initial findings and observations from tests performed on two dwellings, of differing construction and form, in which a coheating test was performed using the dwelling’s central heating system; this method is referred to as integrated coheating. Data obtained during the integrated coheating tests using a dwelling’s heating system have been compared with data obtained during electric coheating of the same dwelling. In one instance, integrated coheating test data from one dwelling was compared to a similar adjoining control dwelling that was simultaneously subject to an electric coheating test. The results show a good agreement between the heat loss coefficients (HLC) obtained using a dwelling’s own heating system and those obtained through electrical coheating. Initial analysis suggests the HLC estimate obtained from integrated coheating is likely to be more representative of how a dwelling performs in-use. The findings question the appropriateness of comparing current steady-state HLC predictions to those derived from in-use monitoring data. Integrated coheating has the potential to provide a more cost-effective and informative indication of whole house heat loss than electric coheating, as it enables in situ quantification of both fabric and heating system performance.
Obtaining the heat loss coefficient of a dwelling using its heating system (integrated coheating)
Farmer, David (Autor:in) / Johnston, David (Autor:in) / Miles-Shenton, Dominic (Autor:in)
Energy and Buildings ; 117 ; 1-10
06.02.2016
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Obtaining the heat loss coefficient of a dwelling using its heating system (integrated coheating)
Online Contents | 2016
|Assessment of the heat loss coefficient of a renovated historical dwelling using a co-heating test
BASE | 2021
|Heat transfer coefficient in dwelling rooms
Engineering Index Backfile | 1934
|HEAT LOSS COEFFICIENT ESTIMATION SYSTEM, HEAT LOSS COEFFICIENT ESTIMATION METHOD, AND PROGRAM
Europäisches Patentamt | 2023
|Laws of heat transmission and heating of dwelling
Engineering Index Backfile | 1950
|