Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Cyclic loading test for concrete-filled U-shaped steel beam–RC column connections
Highlights ► A seismic detail for the concrete filled U-shaped steel beam–RC column connection was developed. ► To verify the seismic performance of the beam–column connection, two full-scale specimens were tested under cyclic loading. ► The test result showed that the specimens exhibited good strength, deformation, and energy dissipation capacities.
Abstract Concrete filled U-shaped steel beams are used to increase the flexural strength and stiffness of the steel beams by using concrete fill. In this study, a seismic detail for the concrete filled U-shaped steel beam–RC column connection was developed. A special detail using diagonal re-bars and welded re-bar connections was used to strengthen the beam–column joints. To verify the seismic performance of the beam–column connection, two full-scale specimens were tested under cyclic loading. The test parameter was the size of the U-shaped steel beam. The depths of the composite beams were 610mm (steel plate thickness=6mm) and 710mm (steel plate thickness=8mm) including the slab depth of 160mm. The test results showed that the specimens exhibited good strength, deformation, and energy dissipation capacities. The deformation capacity exceeded 4% inter-story drift ratio. The primary failure mode of the specimens was buckling and fracture of the steel plate in the beam.
Cyclic loading test for concrete-filled U-shaped steel beam–RC column connections
Highlights ► A seismic detail for the concrete filled U-shaped steel beam–RC column connection was developed. ► To verify the seismic performance of the beam–column connection, two full-scale specimens were tested under cyclic loading. ► The test result showed that the specimens exhibited good strength, deformation, and energy dissipation capacities.
Abstract Concrete filled U-shaped steel beams are used to increase the flexural strength and stiffness of the steel beams by using concrete fill. In this study, a seismic detail for the concrete filled U-shaped steel beam–RC column connection was developed. A special detail using diagonal re-bars and welded re-bar connections was used to strengthen the beam–column joints. To verify the seismic performance of the beam–column connection, two full-scale specimens were tested under cyclic loading. The test parameter was the size of the U-shaped steel beam. The depths of the composite beams were 610mm (steel plate thickness=6mm) and 710mm (steel plate thickness=8mm) including the slab depth of 160mm. The test results showed that the specimens exhibited good strength, deformation, and energy dissipation capacities. The deformation capacity exceeded 4% inter-story drift ratio. The primary failure mode of the specimens was buckling and fracture of the steel plate in the beam.
Cyclic loading test for concrete-filled U-shaped steel beam–RC column connections
Park, Hong-Gun (Autor:in) / Hwang, Hyeon-Jong (Autor:in) / Lee, Cheol-Ho (Autor:in) / Park, Chang-Hee (Autor:in) / Lee, Chang-Nam (Autor:in)
Engineering Structures ; 36 ; 325-336
16.12.2011
12 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Cyclic loading test for concrete-filled U-shaped steel beam–RC column connections
Online Contents | 2012
|