Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
3D Monte Carlo simulation of backscattered electron signal variation across pore-solid boundaries in cement-based materials
Abstract Three-dimensional (3D) Monte Carlo simulation was used to study the variation of backscattered electron (BSE) signal across pore-solid boundaries in cement-based materials in order to enhance quantitative analysis of pore structure. The effects of pore size, depth and boundary inclination angle were investigated. It is found that pores down to 1nm can generate sufficient contrast to be detected. Visibility improves with larger pore size, smaller beam probe size and lower acceleration voltage. However, pixels in shallow pores or near pore boundaries display higher grey values (brightness) than expected due to sampling sub-surface or neighbouring solid material. Thus, cement-based materials may appear less porous or the pores appear smaller than they actually are in BSE images. Simulated BSE images were used to test the accuracy of the Overflow pore segmentation method. Results show the method is generally valid and gives low errors for pores that are 1μm and greater.
3D Monte Carlo simulation of backscattered electron signal variation across pore-solid boundaries in cement-based materials
Abstract Three-dimensional (3D) Monte Carlo simulation was used to study the variation of backscattered electron (BSE) signal across pore-solid boundaries in cement-based materials in order to enhance quantitative analysis of pore structure. The effects of pore size, depth and boundary inclination angle were investigated. It is found that pores down to 1nm can generate sufficient contrast to be detected. Visibility improves with larger pore size, smaller beam probe size and lower acceleration voltage. However, pixels in shallow pores or near pore boundaries display higher grey values (brightness) than expected due to sampling sub-surface or neighbouring solid material. Thus, cement-based materials may appear less porous or the pores appear smaller than they actually are in BSE images. Simulated BSE images were used to test the accuracy of the Overflow pore segmentation method. Results show the method is generally valid and gives low errors for pores that are 1μm and greater.
3D Monte Carlo simulation of backscattered electron signal variation across pore-solid boundaries in cement-based materials
Yio, M.H.N. (Autor:in) / Wong, H.S. (Autor:in) / Buenfeld, N.R. (Autor:in)
Cement and Concrete Research ; 89 ; 320-331
09.09.2016
12 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2016
|British Library Online Contents | 2016
|British Library Online Contents | 2016
|British Library Online Contents | 2016
|