Behavior of ungrouted and unbonded post-tensioned masonry beams and slabs
HighlightsAn improved ungrouted and unbonded post-tensioned masonry system for beams and slabs is devoleped.Tendon restraint blocks were designed to provide nonlinear displacement capacity.Construction time and environmental impact are reduced due to the elimination of grouting.
AbstractThe paper shows and discusses the results of an experimental program aimed at assessing the flexural behavior of ungrouted and unbonded post-tensioned masonry (UUPTM) elements such a beams or two-way slabs. In this structural system, the bed and head mortar joints are excluded and the concrete blocks are post-tensioned with unbonded tendons. A special tendon restraint block has been added to provide nonlinear displacement capacity of the specimens. The global performance is assessed in terms of cracking patterns, failure modes and load-deflection curves. Results from the experimental program indicate that the tendon restraints blocks improve the flexural behavior in terms of strength and nonlinear displacement capacity. Comparison between measured and predicted strength demonstrated that the equations of out-of-plane or in-plane flexural capacity of walls or solid masonry beams provided by building codes for masonry structures, may be used to estimate the maximum flexural capacity of the UUPTM beams having tendon restraint block.
Behavior of ungrouted and unbonded post-tensioned masonry beams and slabs
HighlightsAn improved ungrouted and unbonded post-tensioned masonry system for beams and slabs is devoleped.Tendon restraint blocks were designed to provide nonlinear displacement capacity.Construction time and environmental impact are reduced due to the elimination of grouting.
AbstractThe paper shows and discusses the results of an experimental program aimed at assessing the flexural behavior of ungrouted and unbonded post-tensioned masonry (UUPTM) elements such a beams or two-way slabs. In this structural system, the bed and head mortar joints are excluded and the concrete blocks are post-tensioned with unbonded tendons. A special tendon restraint block has been added to provide nonlinear displacement capacity of the specimens. The global performance is assessed in terms of cracking patterns, failure modes and load-deflection curves. Results from the experimental program indicate that the tendon restraints blocks improve the flexural behavior in terms of strength and nonlinear displacement capacity. Comparison between measured and predicted strength demonstrated that the equations of out-of-plane or in-plane flexural capacity of walls or solid masonry beams provided by building codes for masonry structures, may be used to estimate the maximum flexural capacity of the UUPTM beams having tendon restraint block.
Behavior of ungrouted and unbonded post-tensioned masonry beams and slabs
Bonett, Ricardo L. (Autor:in) / Urrego, Hector (Autor:in) / Carrillo, Julian (Autor:in)
Engineering Structures ; 141 ; 703-714
19.03.2017
12 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Concrete masonry , Post-tensioned , Slabs , Beams , Flexure , Tendon , Restraint block
Flexural behavior of ungrouted post-tensioned concrete masonry beams with unbonded bars
British Library Online Contents | 2019
|Corrosion-induced flexural behavior degradation of locally ungrouted post-tensioned concrete beams
British Library Online Contents | 2017
|Unbonded Post Tensioned Reinforcement in Slabs on Grade
British Library Conference Proceedings | 2005
|Corrosion-induced flexural behavior degradation of locally ungrouted post-tensioned concrete beams
Online Contents | 2017
|