Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic response investigation on CFDST column to steel beam blind-bolted connections
Abstract The blind bolting technique, recognized as a novel solution to connect a beam to a closed section column for unavailable installation from one side, has been gradually employed in concrete filled steel tube (CFST) column to steel beam connections recently. However, unexpected failure modes including bulge of the thin-walled steel tube and anchorage failure of the blind bolt in the core concrete still existed for this type of connection, which resulted in a limited ductility and inferior strength of the connection. Therefore, a novel blind bolted joint was proposed by replacing the CFST column with the concrete-filled double skin steel tubular (CFDST) column to overcome the above problems. A series of interior joint specimens to square CFDST columns were carried out to investigate their seismic behavior. Compared with the CFST column joints, typical failure modes of the CFDST column joints were characterized. Seismic response was also analyzed in terms of the hysteretic performance, strength and stiffness degradation and energy dissipation capacity to explore the effects of the column hollow ratio and end plate type. The experimental results denoted the CFDST column to steel beam joint with blind bolts performed excellent seismic performance. Based on the equivalent method, two simplified analytical models were discussed to evaluate the initial stiffness of this type of joint. The experimental and analytical results were beneficial for the application of semi-rigid connections to CFDST columns in engineering practice.
Highlights Typical failure modes of Steel beam-CFDST column blind bolted interior joints were characterized. Seismic behavior of the blind bolted connection to CFDST column was evaluated. Simplified analytical models based on the equivalent method were discussed to estimate the initial stiffness.
Seismic response investigation on CFDST column to steel beam blind-bolted connections
Abstract The blind bolting technique, recognized as a novel solution to connect a beam to a closed section column for unavailable installation from one side, has been gradually employed in concrete filled steel tube (CFST) column to steel beam connections recently. However, unexpected failure modes including bulge of the thin-walled steel tube and anchorage failure of the blind bolt in the core concrete still existed for this type of connection, which resulted in a limited ductility and inferior strength of the connection. Therefore, a novel blind bolted joint was proposed by replacing the CFST column with the concrete-filled double skin steel tubular (CFDST) column to overcome the above problems. A series of interior joint specimens to square CFDST columns were carried out to investigate their seismic behavior. Compared with the CFST column joints, typical failure modes of the CFDST column joints were characterized. Seismic response was also analyzed in terms of the hysteretic performance, strength and stiffness degradation and energy dissipation capacity to explore the effects of the column hollow ratio and end plate type. The experimental results denoted the CFDST column to steel beam joint with blind bolts performed excellent seismic performance. Based on the equivalent method, two simplified analytical models were discussed to evaluate the initial stiffness of this type of joint. The experimental and analytical results were beneficial for the application of semi-rigid connections to CFDST columns in engineering practice.
Highlights Typical failure modes of Steel beam-CFDST column blind bolted interior joints were characterized. Seismic behavior of the blind bolted connection to CFDST column was evaluated. Simplified analytical models based on the equivalent method were discussed to estimate the initial stiffness.
Seismic response investigation on CFDST column to steel beam blind-bolted connections
Wang, Jingfeng (Autor:in) / Guo, Lei (Autor:in) / Guo, Xiang (Autor:in) / Ding, Zhaodong (Autor:in)
Journal of Constructional Steel Research ; 161 ; 137-153
16.04.2019
17 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Experimental and Analytical Behavior of Square CFDST Column Blind Bolted to Steel Beam Connections
Springer Verlag | 2020
|Bolted Beam - to - Column Steel Connections
British Library Conference Proceedings | 1996
|