Design criteria for insulation materials applied in timber frame assemblies
Insulation materials’ contribution to the fire resistance of timber frame assemblies may vary considerably. At present, Eurocode 5 provides a model for fire design of the load-bearing function of timber frame assemblies with cavities completely filled with stone wool. Very little is known about the fire protection provided by other insulation materials. An improved design model which has the potential to consider the contribution of any insulation material has been introduced by the authors. This paper aims to analyze the parameters that describe in a universal way the protection against the charring given by different insulations not included in Eurocode 5.
A series of model-scale furnace tests of floor specimens for three different insulation materials were carried out. An analysis on the charring depth of the residual cross-sections was conducted by means of a resistograph device.
The study explains the criteria and procedure followed to derive the coefficients for the improved design model for three insulations involved in the study.
This research study involves a large experimental work which forms the basis of the proposed design model. This study presents an important step for fire resistance calculations of timber frame assemblies.
Design criteria for insulation materials applied in timber frame assemblies
Insulation materials’ contribution to the fire resistance of timber frame assemblies may vary considerably. At present, Eurocode 5 provides a model for fire design of the load-bearing function of timber frame assemblies with cavities completely filled with stone wool. Very little is known about the fire protection provided by other insulation materials. An improved design model which has the potential to consider the contribution of any insulation material has been introduced by the authors. This paper aims to analyze the parameters that describe in a universal way the protection against the charring given by different insulations not included in Eurocode 5.
A series of model-scale furnace tests of floor specimens for three different insulation materials were carried out. An analysis on the charring depth of the residual cross-sections was conducted by means of a resistograph device.
The study explains the criteria and procedure followed to derive the coefficients for the improved design model for three insulations involved in the study.
This research study involves a large experimental work which forms the basis of the proposed design model. This study presents an important step for fire resistance calculations of timber frame assemblies.
Design criteria for insulation materials applied in timber frame assemblies
Tiso, Mattia (Autor:in) / Just, Alar (Autor:in)
Journal of Structural Fire Engineering ; 9 ; 252-263
14.11.2017
1 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Fire Protection Provided by Insulation Materials—A New Design Approach for Timber Frame Assemblies
British Library Online Contents | 2017
|TIMBER FRAME STRUCTURES WITH IMPROVED JOINT ASSEMBLIES
Europäisches Patentamt | 2016
|Timber frame structures with improved joint assemblies
Europäisches Patentamt | 2017
|Separating function of light timber frame assemblies
British Library Conference Proceedings | 2006
|Taylor & Francis Verlag | 1985
|