Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Loads on Buildings by Wind-Induced Internal Pressure
The wind load acting on the external walls and roof of buildings corresponds to internal plus external pressure. But whereas external pressure has been studied rather systematically, little information is available on internal pressure. So the aim of this project sponsored by Deutsche Forschungsgemeinschaft was to carry through a systematic investigation of interior pressure relations. The outcome is this systematic study proving the transferability of the majority of the internal pressure results from wind tunnel to nature by means of field and laboratory measurements carried out on a covered tennis court, followed by the systematic investigation of the internal pressures of cubic constructions without internal walls in a wind tunnel. The latter results were prepared to be embodied in relative regulations. This work is the first in a series of systematic studies of wind loads on detached constructions in natural wind using a given wind profile as described by standard 'DIN 1055', so as to be able to choose the appropriate pressure and, thereby, force coefficients in accordance with the profile assumptions. (ERA citation 11:016938)
Loads on Buildings by Wind-Induced Internal Pressure
The wind load acting on the external walls and roof of buildings corresponds to internal plus external pressure. But whereas external pressure has been studied rather systematically, little information is available on internal pressure. So the aim of this project sponsored by Deutsche Forschungsgemeinschaft was to carry through a systematic investigation of interior pressure relations. The outcome is this systematic study proving the transferability of the majority of the internal pressure results from wind tunnel to nature by means of field and laboratory measurements carried out on a covered tennis court, followed by the systematic investigation of the internal pressures of cubic constructions without internal walls in a wind tunnel. The latter results were prepared to be embodied in relative regulations. This work is the first in a series of systematic studies of wind loads on detached constructions in natural wind using a given wind profile as described by standard 'DIN 1055', so as to be able to choose the appropriate pressure and, thereby, force coefficients in accordance with the profile assumptions. (ERA citation 11:016938)
Loads on Buildings by Wind-Induced Internal Pressure
W. Baechlin (Autor:in)
1985
165 pages
Report
Keine Angabe
Englisch
Wind-induced torsional loads on buildings
British Library Online Contents | 1992
|Wind-induced torsional loads on low buildings
Online Contents | 2012
|Wind induced internal pressure overshoot in buildings with opening
Online Contents | 2013
|Wind-Induced Torsional Loads on Low-Rise Buildings
British Library Conference Proceedings | 2011
|Wind-Induced Torsional Loads and Responses of Buildings
ASCE | 2000
|