As a part of the evaluation of a housing system proposed under Operation Breakthrough a standard fire endurance test was performed on a double wall construction representing a non-load-bearing interdwelling wall for single family attached housing. The test followed the requirements of ASTM E 119, Fire Tests of Building Construction and Materials. The double wall which represented an interdwelling separation between two adjacent modules, was made up of two identical parallel walls separated by a 1/2 inch air space. Each wall contained two layers of fire-rated gypsum board attached to wood stud framing on the dwelling room side. Since the test assembly represented a non-bearing wall, no load was applied during this test. The failure of the first (fire exposed) wall and of the second (unexposed) wall were noted. (Modified author abstract)
As a part of the evaluation of a housing system proposed under Operation Breakthrough a standard fire endurance test was performed on a double wall construction representing a non-load-bearing interdwelling wall for single family attached housing. The test followed the requirements of ASTM E 119, Fire Tests of Building Construction and Materials. The double wall which represented an interdwelling separation between two adjacent modules, was made up of two identical parallel walls separated by a 1/2 inch air space. Each wall contained two layers of fire-rated gypsum board attached to wood stud framing on the dwelling room side. Since the test assembly represented a non-bearing wall, no load was applied during this test. The failure of the first (fire exposed) wall and of the second (unexposed) wall were noted. (Modified author abstract)
Fire Endurance Test of a Wood Stud Interdwelling Double Wall Construction
B. C. Son (Autor:in)
1973
22 pages
Report
Keine Angabe
Englisch
Materials Sciences , Building Standards & Codes , Wallboard , Fire tests , Gypsum , Studs(Structural members) , Wooden structures , Residential buildings , Fire safety , Panels , Walls , Durability , Time , Failure , Fire endurance tests , Air space insulation , Breakthrough operation , Flamethrough , Interdwelling walls , Double wall assemblies , Single family dwellings , Attached dwellings , Gypsum board
Fire resistance of wood stud wall assemblies
Wiley | 2021
|Heat transfer through wood-stud wall assemblies exposed to fire
British Library Conference Proceedings | 1992
|Heat transfer through wood-stud wall assemblies exposed to fire