Test Program of Moment-Resistant Steel Beam-To-Column Connections
The objective of the study is to investigate the performance of specified beam-to-column web connections under unsymmetrical loading. Although symmetrically loaded web connections are often found in the interior of building frames, the program concentrates on the more critical case of unsymmetrical loading, the type of loading normally found on the outer column line of buildings. Primary attention is focused upon the moment capacity, rotation capacity, and overall stiffness of web connections.
Test Program of Moment-Resistant Steel Beam-To-Column Connections
The objective of the study is to investigate the performance of specified beam-to-column web connections under unsymmetrical loading. Although symmetrically loaded web connections are often found in the interior of building frames, the program concentrates on the more critical case of unsymmetrical loading, the type of loading normally found on the outer column line of buildings. Primary attention is focused upon the moment capacity, rotation capacity, and overall stiffness of web connections.
Test Program of Moment-Resistant Steel Beam-To-Column Connections
G. P. Rentschler (Autor:in) / W. F. Chen (Autor:in)
1975
43 pages
Report
Keine Angabe
Englisch
Ductile steel beam-column moment connections
Tema Archiv | 1996
|Design of steel beam--column moment connections
British Library Conference Proceedings | 1996
|Performance of ductile steel beam-column moment connections
British Library Conference Proceedings | 1996
|Steel Beam to Large Tubular Column Moment Connections
British Library Conference Proceedings | 1995
|