Anchor Embedment Requirements for Signal/Sign Structures
During the 2004 hurricane season, several anchor embedment failures of the foundations of cantilever sign structures occurred. The purpose of the research program was to determine the cause of the failure of those foundations. After a literature review, in conjunction with site investigation, and testing, it was determined that the failure originated from the shear load on the anchors directed parallel to the edge of the foundation. The shear load resulted from the torsion loading on the anchor group that occurred during the hurricane. Investigation of this failure mode, based on the ACI 318-05 Appendix D provisions for concrete breakout of anchors, indicated that this is a failure mode not considered in the current design procedures for these types of foundations. The results of testing led to the development of guidelines for the evaluation and repair/retrofit of existing foundations. Alternative foundations were also presented for future consideration.
Anchor Embedment Requirements for Signal/Sign Structures
During the 2004 hurricane season, several anchor embedment failures of the foundations of cantilever sign structures occurred. The purpose of the research program was to determine the cause of the failure of those foundations. After a literature review, in conjunction with site investigation, and testing, it was determined that the failure originated from the shear load on the anchors directed parallel to the edge of the foundation. The shear load resulted from the torsion loading on the anchor group that occurred during the hurricane. Investigation of this failure mode, based on the ACI 318-05 Appendix D provisions for concrete breakout of anchors, indicated that this is a failure mode not considered in the current design procedures for these types of foundations. The results of testing led to the development of guidelines for the evaluation and repair/retrofit of existing foundations. Alternative foundations were also presented for future consideration.
Anchor Embedment Requirements for Signal/Sign Structures
R. A. Cook (Autor:in) / K. M. Halcovage (Autor:in)
2007
128 pages
Report
Keine Angabe
Englisch
Embedment Depth Influence on an Uplifting Anchor
ASCE | 2011
|Loss in Anchor Embedment during Plate Anchor Keying in Clay
British Library Online Contents | 2009
|Embedment of poles, sheeting, and anchor piles
Engineering Index Backfile | 1935
|Embedment of poles, sheeting, and anchor piles
Engineering Index Backfile | 1934
|Loss in Anchor Embedment during Plate Anchor Keying in Clay
Online Contents | 2009
|