Simple Procedure for Assessing Thermal Comfort in Passive Solar Heated Buildings
The Fanger thermal comfort equation is linearized and used to develop a procedure for assessing thermal comfort levels in passive solar heated buildings. In order to relate comfort levels in nonuniform environments to uniform conditions, a new thermal index called the equivalent uniform temperature is introduced. (ERA citation 04:042678)
Simple Procedure for Assessing Thermal Comfort in Passive Solar Heated Buildings
The Fanger thermal comfort equation is linearized and used to develop a procedure for assessing thermal comfort levels in passive solar heated buildings. In order to relate comfort levels in nonuniform environments to uniform conditions, a new thermal index called the equivalent uniform temperature is introduced. (ERA citation 04:042678)
Simple Procedure for Assessing Thermal Comfort in Passive Solar Heated Buildings
W. O. Wray (Autor:in)
1979
6 pages