During January and May, 2009, two configurations of steel-framed walls constructed with conventional 2 x 4 steel studs insulated with either R-19, approximately 14 cm (5.5 in.) thick, or R-13, approximately 9 cm (3.5 in.) thick, fiberglass insulation batts were tested in the Oak Ridge National Laboratory (ORNL) guarded hot box using the ASTM Standard C1363 test procedure. The first test wall used conventional 2 x 4 steel studs insulated with 2.5 cm (1 in.) thick foam profiles, called stud-snugglers. These stud-snugglers converted the 2 x 4 wall assembly into a 2 x 6 assembly, allowing application of R-19 fiberglass insulation. The second wall tested for comparison was a conventional 2 x 4 steel stud wall using R-13 insulation batts. Furthermore, numerical simulations were performed in order to evaluate the steady-state thermal performance of various wood- and steel-framed wall assemblies. The effects of adding the stud-snugglers to the wood and steel studs were also investigated numerically. Different combinations of insulation and framing factor were used in the simulations.
During January and May, 2009, two configurations of steel-framed walls constructed with conventional 2 x 4 steel studs insulated with either R-19, approximately 14 cm (5.5 in.) thick, or R-13, approximately 9 cm (3.5 in.) thick, fiberglass insulation batts were tested in the Oak Ridge National Laboratory (ORNL) guarded hot box using the ASTM Standard C1363 test procedure. The first test wall used conventional 2 x 4 steel studs insulated with 2.5 cm (1 in.) thick foam profiles, called stud-snugglers. These stud-snugglers converted the 2 x 4 wall assembly into a 2 x 6 assembly, allowing application of R-19 fiberglass insulation. The second wall tested for comparison was a conventional 2 x 4 steel stud wall using R-13 insulation batts. Furthermore, numerical simulations were performed in order to evaluate the steady-state thermal performance of various wood- and steel-framed wall assemblies. The effects of adding the stud-snugglers to the wood and steel studs were also investigated numerically. Different combinations of insulation and framing factor were used in the simulations.
Steady-State Thermal Performance Evaluation of Steel-Framed Wall Assembly with Local Foam Insulation
2010
10 pages
Report
Keine Angabe
Englisch
Thermal insulation and thermal bridge of steel-framed walls
Tema Archiv | 1999
|High insulation performance of steel-framed house by exterior insulation
Tema Archiv | 1998
|Thermal and sound insulation of lightweight steel-framed façade walls
Taylor & Francis Verlag | 2019
|