Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Grout Treatment Facility waste feed acceptance criteria. Revision 1
This document establishes criteria for the acceptance of grout waste feed to provide assurance that the final grout form produced by the Grout Disposal Facility (GDF) will meet the regulatory, design, product, and process requirements. Contained in the report is an evaluation of the regulatory requirements associated with the grout disposal option along with a description of the waste currently stored on the site. An evaluation of the heat generation requirements for the waste feed stream is presented. This evaluation includes the heat resulting from the grout curing process as well as heat associated with the radiolytic decay of the radioisotopes present. Limits for individual elements as well as limits for classes of materials such as organics, sulfates, etc. are presented in Table 1-1. These values are based on regulatory, heat generation, and compositional limits to assure the integrity of the final grout products. Some compositional limits such as heavy metals will require Toxicity Characteristic Leaching Procedure (TCLP) testing to demonstrate regulatory compliance.
Grout Treatment Facility waste feed acceptance criteria. Revision 1
This document establishes criteria for the acceptance of grout waste feed to provide assurance that the final grout form produced by the Grout Disposal Facility (GDF) will meet the regulatory, design, product, and process requirements. Contained in the report is an evaluation of the regulatory requirements associated with the grout disposal option along with a description of the waste currently stored on the site. An evaluation of the heat generation requirements for the waste feed stream is presented. This evaluation includes the heat resulting from the grout curing process as well as heat associated with the radiolytic decay of the radioisotopes present. Limits for individual elements as well as limits for classes of materials such as organics, sulfates, etc. are presented in Table 1-1. These values are based on regulatory, heat generation, and compositional limits to assure the integrity of the final grout products. Some compositional limits such as heavy metals will require Toxicity Characteristic Leaching Procedure (TCLP) testing to demonstrate regulatory compliance.
Grout Treatment Facility waste feed acceptance criteria. Revision 1
D. W. Hendrickson (Autor:in)
1991
68 pages
Report
Keine Angabe
Englisch