Transmission of Low-Magnitude Seismic Excitation into Hanford Site Structures
Several Hanford Site buildings were analyzed using simplified models to gain insight as to what extent the free field motion of a small-magnitude earthquake is transmitted into building structures as a result of soil-structure interaction effects. Building selection included the Plutonium Processing Plant, B-Plant and the Fast Flux Test Facility containment which represented a variety of stiffnesses, weights, and embedments. An artificial time history for the free field has a peak response at 13 Hz. This motion represents a median for magnitude 4 and 4.5 earthquakes, respectively. Floor response spectra were compared with results from analyses to design basis ground motions using the same structural models. Considerable attenuation of the small-magnitude free-field motion was found in the case of stiff, deeply embedded structures. This attenuation is attributed to kinematic interaction in addition to attenuation with depth in the free field. Even with such attenuation, there are exceptions where small magnitude responses exceed design basis responses. They are generally associated with 10 to 20 Hz modes with vertical motion. 6 refs., 6 figs., 1 tab.
Transmission of Low-Magnitude Seismic Excitation into Hanford Site Structures
Several Hanford Site buildings were analyzed using simplified models to gain insight as to what extent the free field motion of a small-magnitude earthquake is transmitted into building structures as a result of soil-structure interaction effects. Building selection included the Plutonium Processing Plant, B-Plant and the Fast Flux Test Facility containment which represented a variety of stiffnesses, weights, and embedments. An artificial time history for the free field has a peak response at 13 Hz. This motion represents a median for magnitude 4 and 4.5 earthquakes, respectively. Floor response spectra were compared with results from analyses to design basis ground motions using the same structural models. Considerable attenuation of the small-magnitude free-field motion was found in the case of stiff, deeply embedded structures. This attenuation is attributed to kinematic interaction in addition to attenuation with depth in the free field. Even with such attenuation, there are exceptions where small magnitude responses exceed design basis responses. They are generally associated with 10 to 20 Hz modes with vertical motion. 6 refs., 6 figs., 1 tab.
Transmission of Low-Magnitude Seismic Excitation into Hanford Site Structures
E. O. Weiner (Autor:in)
1989
8 pages
Report
Keine Angabe
Englisch
A Seismic Landstreamer Survey at the Hanford Site, Washington, U.S.A.
Online Contents | 2011
|Shielding research at the Hanford Site
NTIS | 1992
|Risk-Based Prioritization at Hanford Nuclear Site
British Library Conference Proceedings | 1995
|Hanford site post NPH building inspection plan
NTIS | 1996
|Hanford Site Asbestos Abatement Plan (HSAAP). Revision 1
NTIS | 1995
|