Full-Scale Fire Tests with Automatic Sprinklers in a Patient Room. Phase II
The Center for Fire Research conducted a series of full-scale fire tests in a patient room and corridor arrangement to examine the use of automatic sprinklers in patient rooms of health care facilities. This is a report of twenty-one (21) fire tests in which either mattresses with bedding or clothing wardrobes served as the burning items. Test results indicated that actuation of both pendant and horizontal sidewall sprinklers in the patient room acted to cool and redistribute the combustion products in the patient room and in the corridor away from the flowing sprinkler. This phenomena resulted in total obscuration throughout the test area. It was demonstrated that the use of a fast response, (low thermal inertia) sprinkler resulted in significantly less smoke obscuration in the mattress and bedding fires. Sprinkler spray distribution measurements were made to develop criteria for the position of privacy curtains with respect to the automatic sprinklers in the patient room. Recommended installation criteria are provided. Analysis of the test results indicated that the combustible clothing wardrobe fire resulted in room flashover in a nonsprinklered test. In several tests with sprinklers, flashover did not occur, however, estimated hazardous thresholds for carbon monoxide were still exceeded in the test area. It was determined that the combustible construction of the wardrobe primarily contributed to the high concentrations of carbon monoxide.
Full-Scale Fire Tests with Automatic Sprinklers in a Patient Room. Phase II
The Center for Fire Research conducted a series of full-scale fire tests in a patient room and corridor arrangement to examine the use of automatic sprinklers in patient rooms of health care facilities. This is a report of twenty-one (21) fire tests in which either mattresses with bedding or clothing wardrobes served as the burning items. Test results indicated that actuation of both pendant and horizontal sidewall sprinklers in the patient room acted to cool and redistribute the combustion products in the patient room and in the corridor away from the flowing sprinkler. This phenomena resulted in total obscuration throughout the test area. It was demonstrated that the use of a fast response, (low thermal inertia) sprinkler resulted in significantly less smoke obscuration in the mattress and bedding fires. Sprinkler spray distribution measurements were made to develop criteria for the position of privacy curtains with respect to the automatic sprinklers in the patient room. Recommended installation criteria are provided. Analysis of the test results indicated that the combustible clothing wardrobe fire resulted in room flashover in a nonsprinklered test. In several tests with sprinklers, flashover did not occur, however, estimated hazardous thresholds for carbon monoxide were still exceeded in the test area. It was determined that the combustible construction of the wardrobe primarily contributed to the high concentrations of carbon monoxide.
Full-Scale Fire Tests with Automatic Sprinklers in a Patient Room. Phase II
J. G. O'Neill (Autor:in) / W. D. Hayes (Autor:in) / R. H. Zile (Autor:in)
1980
96 pages
Report
Keine Angabe
Englisch
Automatic sprinklers of fire protection
Engineering Index Backfile | 1892
|Automatic Fire Detection and Sprinklers
British Library Online Contents | 1994
|