Solar building study. Final report. Victoria House. Hampshire Constabulary training and support headquarters, Netley
A report is given of the energy performance of a solar building at the Police Training Headquarters at Netley in the UK. Total fuel use for the building was 313.6 kWh/m(sup 2). This compared very unfavourably with other similar building types. The excellent daylighting in the modern additions to the building produced substantial lighting energy savings. Unfortunately, these were more than negated by the very substantial heat loss through the retained Victorian sash windows, and the poor match between heating system and building occupancy. With the exception of some overheating in the north facing offices the modern additions to the building were thermally comfortable. Discomfort occurred in other areas due to several problems, partly associated with the retained Victorian sash windows. Whilst the atrium played a central role in the building's success as a training facility the effectiveness of the natural ventilation strategy incorporated within it was hampered by a series of conflicts. At pound641/m(sup 2) GFA 3923m(sup 2) (December 1990), the normalised cost of the renovation was reasonable in comparison with reference cost figures. (author)
Solar building study. Final report. Victoria House. Hampshire Constabulary training and support headquarters, Netley
A report is given of the energy performance of a solar building at the Police Training Headquarters at Netley in the UK. Total fuel use for the building was 313.6 kWh/m(sup 2). This compared very unfavourably with other similar building types. The excellent daylighting in the modern additions to the building produced substantial lighting energy savings. Unfortunately, these were more than negated by the very substantial heat loss through the retained Victorian sash windows, and the poor match between heating system and building occupancy. With the exception of some overheating in the north facing offices the modern additions to the building were thermally comfortable. Discomfort occurred in other areas due to several problems, partly associated with the retained Victorian sash windows. Whilst the atrium played a central role in the building's success as a training facility the effectiveness of the natural ventilation strategy incorporated within it was hampered by a series of conflicts. At pound641/m(sup 2) GFA 3923m(sup 2) (December 1990), the normalised cost of the renovation was reasonable in comparison with reference cost figures. (author)
Solar building study. Final report. Victoria House. Hampshire Constabulary training and support headquarters, Netley
N. Vaughan (Autor:in) / P. Jones (Autor:in) / D. Alexander (Autor:in) / H. Jenkins (Autor:in) / M. Fedeski (Autor:in)
1992
126 pages
Report
Keine Angabe
Englisch
Constabulary in Lauterach, Austria
British Library Online Contents | 2006
|Lloyd's Register of Shipping Headquarters, Hampshire
British Library Conference Proceedings | 1996
|