Nondestructive Condition Assessment of a Posted Bridge
The primary objective for the Tindall Bridge study was to demonstrate how it would be possible to design the restoration and preservation of a historic bridge by integrating advanced technologies with sound, heuristic-based structural engineering. The University of Cincinnati Infrastructure Institute (UCII) team of engineers used their experience in field instrumentation and diagnostic truck-load testing, structural system-identification, structural-steel design, and materials-engineering to conduct an evaluation of the Tindall Bridge in Sandusky County, Ohio (BA-209-0.05, constructed 1915). Since the critical material and structural attributes of the bridge were proven to be excellent, a strategy was designed for its preservation. First, critical retrofit was designed at the main roller supports; this was urgently needed to mitigate possible failure modes. Second, preventive maintenance and minor restoration, directed mainly at the floor-system and sub-structure, were designed to ascertain a safe operating service life of five to seven years. Finally, measures were designed to structurally reinforce the floor-system, which features an open grate deck, in order to ensure a subsequent fifteen to twenty year service life.
Nondestructive Condition Assessment of a Posted Bridge
The primary objective for the Tindall Bridge study was to demonstrate how it would be possible to design the restoration and preservation of a historic bridge by integrating advanced technologies with sound, heuristic-based structural engineering. The University of Cincinnati Infrastructure Institute (UCII) team of engineers used their experience in field instrumentation and diagnostic truck-load testing, structural system-identification, structural-steel design, and materials-engineering to conduct an evaluation of the Tindall Bridge in Sandusky County, Ohio (BA-209-0.05, constructed 1915). Since the critical material and structural attributes of the bridge were proven to be excellent, a strategy was designed for its preservation. First, critical retrofit was designed at the main roller supports; this was urgently needed to mitigate possible failure modes. Second, preventive maintenance and minor restoration, directed mainly at the floor-system and sub-structure, were designed to ascertain a safe operating service life of five to seven years. Finally, measures were designed to structurally reinforce the floor-system, which features an open grate deck, in order to ensure a subsequent fifteen to twenty year service life.
Nondestructive Condition Assessment of a Posted Bridge
A. E. Aktan (Autor:in) / D. N. Farhey (Autor:in) / R. Naghavi (Autor:in) / A. Levi (Autor:in) / A. M. Thakur (Autor:in)
1997
208 pages
Report
Keine Angabe
Englisch
Nondestructive Assessment of Unknown Bridge Condition
British Library Conference Proceedings | 1998
|Nondestructive Assessment of Unknown Bridge Condition
British Library Conference Proceedings | 1999
|Experimental Load Rating of a Posted Bridge
Online Contents | 1997
|Bridge-Condition Assessment and Load Rating Using Nondestructive Evaluation Methods
British Library Online Contents | 2000
|