Cathodic activation, anodic and immersion passivation treatments on types 310, 321, 410 stainless steel panels, and M1 gas cylinders were investigated in 5% solutions of Na2SO4, Na2Cr2O7. Passivation in 20% HNO3 containing 2% Na2Cr2O7 was conducted as described in MIL-STD171A. A Sargent Recorder, Model MR, an automatic self-balancing potentiometer, was used to measure potentials with reference to a normal Calomel-cell and a salt bridge in contact with a stainless steel panel in an auxiliary vessel containing 0.001N NaC1. Potential vs. time measurements were plotted graphically to show the effects of the treatments on the stainless steels. Passivation treatments increased the positive potential; activation increased the negative potential; half-cell potential measurements showed a decay in panel potential vs. time in air exposure. Passivated panels in salt spray exposure afforded slightly better protection than the control panels. Passivated panels in outdoor exposure showed no appreciable difference between the types of stainless steels in the prevention of corrosion. (Author)
Cathodic activation, anodic and immersion passivation treatments on types 310, 321, 410 stainless steel panels, and M1 gas cylinders were investigated in 5% solutions of Na2SO4, Na2Cr2O7. Passivation in 20% HNO3 containing 2% Na2Cr2O7 was conducted as described in MIL-STD171A. A Sargent Recorder, Model MR, an automatic self-balancing potentiometer, was used to measure potentials with reference to a normal Calomel-cell and a salt bridge in contact with a stainless steel panel in an auxiliary vessel containing 0.001N NaC1. Potential vs. time measurements were plotted graphically to show the effects of the treatments on the stainless steels. Passivation treatments increased the positive potential; activation increased the negative potential; half-cell potential measurements showed a decay in panel potential vs. time in air exposure. Passivated panels in salt spray exposure afforded slightly better protection than the control panels. Passivated panels in outdoor exposure showed no appreciable difference between the types of stainless steels in the prevention of corrosion. (Author)
Anodic Passivation of Stainless Steel
L. H. Wagner (Autor:in)
1965
2 pages
Report
Keine Angabe
Englisch
Passivation of Stainless Steel
Online Contents | 1998
|Field Passivation Technology for Stainless Steel
British Library Online Contents | 2014
|Passivation of welded AISI 316L stainless steel
British Library Online Contents | 2008
|Anodic behaviour of supermartensitic stainless steel weldments
British Library Online Contents | 2010
|Technique of Chromium-Free Passivation of 316L Stainless Steel
British Library Online Contents | 2001
|