Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Indoor ozone concentrations: Ventilation rate impacts and mechanisms of outdoor concentration attenuation
The classification of outdoor (ambient) air as fresh for the purposes of ventilation is not always appropriate, particularly in urban areas. In many cities of the world, urban air frequently violates health-based air quality standards due to high ozone concentrations. The degree of protection from exposure to ozone offered by the indoor environment depends on the relationship between indoor and outdoor ozone levels. Existing concentration data indicates that indoor/outdoor ozone ratios range between 10 and 80%. This paper analyzes several of the key issues influencing indoor ozone concentrations, including: (1) the degree of penetration of outdoor ozone indoors, (2) removal within the indoor environment (removal at surfaces and within air distribution systems), and (3) the correlation in time between outdoor ozone levels and ventilation rates. A model for calculating the degree of ozone removal in typical building leaks and air distribution systems is described and applied to a range of typical cases. This model indicates that the degree of removal is minimal for most wooden building cracks, but could be significant in leaks in concrete or brick structures, and is strongly dependent on the lining material for air distribution systems. Indoor ozone exposure estimates based on hourly outdoor ozone monitoring data and hour-by-hour weather-based simulations of infiltration rates and building operation are reported for a few residential scenarios. These estimates serve as a basis for exploring the impact of energy-efficient ventilation strategies on indoor ozone exposures.
Indoor ozone concentrations: Ventilation rate impacts and mechanisms of outdoor concentration attenuation
The classification of outdoor (ambient) air as fresh for the purposes of ventilation is not always appropriate, particularly in urban areas. In many cities of the world, urban air frequently violates health-based air quality standards due to high ozone concentrations. The degree of protection from exposure to ozone offered by the indoor environment depends on the relationship between indoor and outdoor ozone levels. Existing concentration data indicates that indoor/outdoor ozone ratios range between 10 and 80%. This paper analyzes several of the key issues influencing indoor ozone concentrations, including: (1) the degree of penetration of outdoor ozone indoors, (2) removal within the indoor environment (removal at surfaces and within air distribution systems), and (3) the correlation in time between outdoor ozone levels and ventilation rates. A model for calculating the degree of ozone removal in typical building leaks and air distribution systems is described and applied to a range of typical cases. This model indicates that the degree of removal is minimal for most wooden building cracks, but could be significant in leaks in concrete or brick structures, and is strongly dependent on the lining material for air distribution systems. Indoor ozone exposure estimates based on hourly outdoor ozone monitoring data and hour-by-hour weather-based simulations of infiltration rates and building operation are reported for a few residential scenarios. These estimates serve as a basis for exploring the impact of energy-efficient ventilation strategies on indoor ozone exposures.
Indoor ozone concentrations: Ventilation rate impacts and mechanisms of outdoor concentration attenuation
J. A. Cano-Ruiz (Autor:in) / M. P. Modera (Autor:in) / W. W. Nazaroff (Autor:in)
1992
20 pages
Report
Keine Angabe
Englisch
Air Pollution & Control , Architectural Design & Environmental Engineering , Environmental Management & Planning , Buildings , Ozone , Indoor Air Pollution , Ventilation , Air Flow , Ecological Concentration , Energy Efficiency , Environmental Exposure , Urban Areas , Ventilation Systems , Walls , Meetings , EDB/320107 , EDB/540120
Indoor Formaldehyde Concentration and Ventilation Rate
British Library Conference Proceedings | 1994
|Evaluation of Indoor Ozone Concentration and Predictors of Indoor-Outdoor Ratio in Mexico City
Taylor & Francis Verlag | 1998
|Air control dustproof indoor and outdoor ventilation window
Europäisches Patentamt | 2022
|