A 2000-ft exp 2 single-family residence was constructed during the second quarter of 1976 to demonstrate the energy-conserving features of additional insulation, a ventilation cooling cycle, and the Annual Cycle Energy System (ACES). The ACES is an integrated heating and cooling system that supplies space heating, hot water, and space cooling using a heat pump and low-temperature thermal storage. Included in this report are a discussion of the construction techniques employed and the problems encountered during construction, a description of the ACES concept and the ACES mechanical package, and a discussion of the ACES performance and the experiences obtained during initial operation of the ACES. Continuous operation and data collection were begun in May 1977. Performance data from November 1977 through March 1978 have shown a seasonal heating coefficient of performance of 2.77 for the ACES, giving a 63% energy reduction compared to electric resistance space and water heating. (ERA citation 04:008404)
ACES Demonstration: Construction, Startup, and Performance Report
A 2000-ft exp 2 single-family residence was constructed during the second quarter of 1976 to demonstrate the energy-conserving features of additional insulation, a ventilation cooling cycle, and the Annual Cycle Energy System (ACES). The ACES is an integrated heating and cooling system that supplies space heating, hot water, and space cooling using a heat pump and low-temperature thermal storage. Included in this report are a discussion of the construction techniques employed and the problems encountered during construction, a description of the ACES concept and the ACES mechanical package, and a discussion of the ACES performance and the experiences obtained during initial operation of the ACES. Continuous operation and data collection were begun in May 1977. Performance data from November 1977 through March 1978 have shown a seasonal heating coefficient of performance of 2.77 for the ACES, giving a 63% energy reduction compared to electric resistance space and water heating. (ERA citation 04:008404)
ACES Demonstration: Construction, Startup, and Performance Report
A. S. Holman (Autor:in) / V. R. Brantley (Autor:in)
1978
86 pages
Report
Keine Angabe
Englisch
Heating & Cooling Systems , Architectural Design & Environmental Engineering , Annual cycle energy system , Air conditioning , Construction , Data acquisition , Design , Energy conservation , Heat pumps , Heat storage , Hot water , Houses , Implementation , Operation , Performance , Residential sector , Space heating , Thermal insulation , Ventilation systems , ERDA/291000 , ERDA/320101 , Residential buildings
Online Contents | 2014
|RUBBER FLOORING ACES SCHOOL STANDARDS FOR MAINTENANCE
British Library Online Contents | 2016
|