Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
The Impact of Building Code Criteria and Emergency Prepardness Criteria on Water Demand Requirements to Fire Protection
This study is concerned with providing a source document on the four model building codes, published standards and civil preparedness criteria relative to their influence on water demand requirements for domestic and fire protection needs. These water demand requirements for fire protection are calculated by four existing methods determined to be the most appropriate and an additional method derived from theoretically and empirically-based concepts. These methods are compared and contrasted relative to the model building code and civil preparedness criteria. The water supply requirements for domestic usage are calculated by an existing technique, the results of which are compared to the fire protection related water demand. Because of the conclusions and limitations noted in this study relative to the concept of water demand requirements in the event of crisis relocation, several areas are identified which future research endeavors should consider. (Author)
The Impact of Building Code Criteria and Emergency Prepardness Criteria on Water Demand Requirements to Fire Protection
This study is concerned with providing a source document on the four model building codes, published standards and civil preparedness criteria relative to their influence on water demand requirements for domestic and fire protection needs. These water demand requirements for fire protection are calculated by four existing methods determined to be the most appropriate and an additional method derived from theoretically and empirically-based concepts. These methods are compared and contrasted relative to the model building code and civil preparedness criteria. The water supply requirements for domestic usage are calculated by an existing technique, the results of which are compared to the fire protection related water demand. Because of the conclusions and limitations noted in this study relative to the concept of water demand requirements in the event of crisis relocation, several areas are identified which future research endeavors should consider. (Author)
The Impact of Building Code Criteria and Emergency Prepardness Criteria on Water Demand Requirements to Fire Protection
H. E. Hickey (Autor:in) / J. A. Milke (Autor:in)
1979
137 pages
Report
Keine Angabe
Englisch
Building Standards & Codes , Building Equipment, Furnishings, & Maintenance , Environmental Management & Planning , Fire Services, Law Enforcement, & Criminal Justice , Emergency Services & Planning , Fire protection , Water supplies , Fires , Water flow , Requirements , Crisis management , Relocation , Buildings , State law , Crisis relocation , Building codes , Emergency preparedness
Second Look at Fire Protection Code Criteria
NTIS | 1985
|Fire Protection: Understanding Building Code Requirements
British Library Online Contents | 1996
Fire protection design criteria
NTIS | 1997
Technical Requirements and Building Criteria
British Library Conference Proceedings | 1992
|Fire Safety Requirements and Criteria for Dwellings
NTIS | 1975
|