Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparative Analysis of Chlorophyll-a Distribution from SeaWiFS, MODIS-Aqua, MODIS-Terra and MERIS in the Arabian Sea
The variability of Chlorophyll-a (Chl-a) distribution derived from MODIS (on Aqua and Terra platforms) and MERIS sensors have been compared with SeaWiFS data in the Arabian Sea. MODIS Aqua has overestimated the SeaWiFS Chl-a within 25-32% in the coastal turbid (eutrophic) waters and underestimated in open ocean waters with error within 20%. However, there is no significant bias (−0.1 on log-scale) observed as the slope is well within 0.97-1.1 (log transformed). MODIS-Terra has underestimated the Chl-a concentration in open ocean waters by about 29-31%, which is higher than MODIS-Aqua. MODIS-Terra is observed to be more accurate than MODIS-Aqua in the coastal waters. MERIS is overestimating the SeaWiFS Chl-a with log RMS error of ∼0.15 and log bias of ∼0.13-0.2. The differences in the Chl-a estimates between each sensor are possibly due to differences in the sensor design, bio-optical algorithms and also due to the time differences between the satellites over passes. We have examined that the MERIS is performing similar to SeaWiFS and the MODIS-Aqua (Terra) data are reliable in open ocean (coastal) waters. However, Chl-a retrieval algorithms need to be improved especially for coastal turbid waters to continue with SeaWiFS data for long-term studies.
Comparative Analysis of Chlorophyll-a Distribution from SeaWiFS, MODIS-Aqua, MODIS-Terra and MERIS in the Arabian Sea
The variability of Chlorophyll-a (Chl-a) distribution derived from MODIS (on Aqua and Terra platforms) and MERIS sensors have been compared with SeaWiFS data in the Arabian Sea. MODIS Aqua has overestimated the SeaWiFS Chl-a within 25-32% in the coastal turbid (eutrophic) waters and underestimated in open ocean waters with error within 20%. However, there is no significant bias (−0.1 on log-scale) observed as the slope is well within 0.97-1.1 (log transformed). MODIS-Terra has underestimated the Chl-a concentration in open ocean waters by about 29-31%, which is higher than MODIS-Aqua. MODIS-Terra is observed to be more accurate than MODIS-Aqua in the coastal waters. MERIS is overestimating the SeaWiFS Chl-a with log RMS error of ∼0.15 and log bias of ∼0.13-0.2. The differences in the Chl-a estimates between each sensor are possibly due to differences in the sensor design, bio-optical algorithms and also due to the time differences between the satellites over passes. We have examined that the MERIS is performing similar to SeaWiFS and the MODIS-Aqua (Terra) data are reliable in open ocean (coastal) waters. However, Chl-a retrieval algorithms need to be improved especially for coastal turbid waters to continue with SeaWiFS data for long-term studies.
Comparative Analysis of Chlorophyll-a Distribution from SeaWiFS, MODIS-Aqua, MODIS-Terra and MERIS in the Arabian Sea
Arun Kumar, S. V. V (Autor:in) / Babu, K. N / Shukla, A. K
Marine geodesy ; 38
2015
Aufsatz (Zeitschrift)
Englisch
Sampling biases in MODIS and SeaWiFS ocean chlorophyll data
Online Contents | 2007
|Corrections to the Calibration of MODIS Aqua Ocean Color Bands Derived From SeaWiFS Data
Online Contents | 2012
|