Impact of Improved Calibration of a NEO HySpex VNIR-1600 Sensor on Remote Sensing of Water Depth
This paper investigates at the example of bathymetry how much an application can profit from comprehensive characterizations required for an improved calibration of data from a state-of-the-art commercial hyperspectral sensor. A NEO HySpex VNIR-1600 sensor is used for this paper, and the improvements are based on measurements of sensor properties not covered by the manufacturer, in particular, detector nonlinearity and stray light. This additional knowledge about the instrument is used to implement corrections for nonlinearity, stray light, spectral smile distortion and nonuniform spectral bandwidth and to base the radiometric calibration on a SI-traceable radiance standard. Bathymetry is retrieved from a data take from the lake Starnberg using WASI-2D. The results using the original and improved calibration procedures are compared with ground reference data, with an emphasis on the effect of stray-light correction. For our instrument, stray-light biases the detector response from 416-500 nm up to 8% and from 700-760 nm up to 5%. Stray-light-induced errors affect bathymetry mainly in water deeper than Secchi depth, whereas in shallower water, the dominant error source is the calibration accuracy of the light source used for radiometric calibration. Stray-light correction reduced the systematic error of water depth by 19% from Secchi depth to three times Secchi depth, whereas the relative standard deviation remained stable at 5%.
Impact of Improved Calibration of a NEO HySpex VNIR-1600 Sensor on Remote Sensing of Water Depth
This paper investigates at the example of bathymetry how much an application can profit from comprehensive characterizations required for an improved calibration of data from a state-of-the-art commercial hyperspectral sensor. A NEO HySpex VNIR-1600 sensor is used for this paper, and the improvements are based on measurements of sensor properties not covered by the manufacturer, in particular, detector nonlinearity and stray light. This additional knowledge about the instrument is used to implement corrections for nonlinearity, stray light, spectral smile distortion and nonuniform spectral bandwidth and to base the radiometric calibration on a SI-traceable radiance standard. Bathymetry is retrieved from a data take from the lake Starnberg using WASI-2D. The results using the original and improved calibration procedures are compared with ground reference data, with an emphasis on the effect of stray-light correction. For our instrument, stray-light biases the detector response from 416-500 nm up to 8% and from 700-760 nm up to 5%. Stray-light-induced errors affect bathymetry mainly in water deeper than Secchi depth, whereas in shallower water, the dominant error source is the calibration accuracy of the light source used for radiometric calibration. Stray-light correction reduced the systematic error of water depth by 19% from Secchi depth to three times Secchi depth, whereas the relative standard deviation remained stable at 5%.
Impact of Improved Calibration of a NEO HySpex VNIR-1600 Sensor on Remote Sensing of Water Depth
Lenhard, Karim (Autor:in) / Baumgartner, Andreas / Gege, Peter / Nevas, Saulius / Nowy, Stefan / Sperling, Armin
2015
Aufsatz (Zeitschrift)
Englisch
Lokalklassifikation TIB:
770/3710/5670
BKL:
38.03
Methoden und Techniken der Geowissenschaften
/
74.41
Luftaufnahmen, Photogrammetrie
TIBKAT | 2024
|Land Surface Emissivity Retrieval From Different VNIR and TIR Sensors
Online Contents | 2008
|ANALYSIS OF CONCRETE REFLECTANCE CHARACTERISTICS USING SPECTROMETER AND VNIR HYPERSPECTRAL CAMERA
DOAJ | 2012
|Application of Model-Based Change Detection to Airborne VNIR/SWIR Hyperspectral Imagery
Online Contents | 2012
|