Performance of micropiled raft in clay subjected to vertical concentrated load: centrifuge modeling
The overall behavior of a micropiled raft foundation (MPR) system is similar to a piled raft foundation where the load is transferred by both the raft and micropiles. However, there is no guidance available regarding the design of MPRs or indication of their performance. In this study, geotechnical centrifuge testing was conducted to investigate the behavior of MPR foundations in clay and evaluate their performance characteristics. The study evaluated the performance of MPRs compared to the isolated raft in terms of raft total and differential settlements; raft contact pressure; raft bending moment; and load sharing between the raft and the micropiles. The results showed that for the MPR configuration considered in the study, the raft carried 48% of the applied load. It was found that the Poulos–Davis–Randolph (PDR) method can be used to evaluate the performance of MPR for preliminarily design purposes with approximately 17% error.
Le comportement global d’une structure de fondation sur micropieux et radier (MPR) est similaire à celui d’une fondation constituée d’un radier sur pieux, dans laquelle la charge est à la fois transférée par le radier et les micropieux. Cependant, il n’existe actuellement aucune norme en matière de conception de fondations sur MPR ni de données sur leurs performances. Dans la présente étude, des essais géotechniques en centrifugeuse ont été réalisés pour étudier le comportement de fondations sur MPR construites dans l’argile et évaluer leurs paramètres de performance. Dans cette étude, on a évalué les performances des MPR par rapport à celles d’un radier, en examinant le tassement total et différentiel du radier, la pression de contact exercée sur le radier, le moment de flexion dans le radier et la répartition de la charge entre le radier et les micropieux. Les résultats ont montré que, dans la configuration MPR choisie ici, le radier supportait 48 % de la charge appliquée sur l’ensemble de la structure de fondation. On a également constaté que la méthode de Poulos–Davis–Randolph (PDR) pouvait servir à évaluer, avec une marge d’erreur d’environ 17 %, les performances d’une fondation sur MPR lors de l’étape de conception préliminaire. [Traduit par la Rédaction]
Performance of micropiled raft in clay subjected to vertical concentrated load: centrifuge modeling
The overall behavior of a micropiled raft foundation (MPR) system is similar to a piled raft foundation where the load is transferred by both the raft and micropiles. However, there is no guidance available regarding the design of MPRs or indication of their performance. In this study, geotechnical centrifuge testing was conducted to investigate the behavior of MPR foundations in clay and evaluate their performance characteristics. The study evaluated the performance of MPRs compared to the isolated raft in terms of raft total and differential settlements; raft contact pressure; raft bending moment; and load sharing between the raft and the micropiles. The results showed that for the MPR configuration considered in the study, the raft carried 48% of the applied load. It was found that the Poulos–Davis–Randolph (PDR) method can be used to evaluate the performance of MPR for preliminarily design purposes with approximately 17% error.
Le comportement global d’une structure de fondation sur micropieux et radier (MPR) est similaire à celui d’une fondation constituée d’un radier sur pieux, dans laquelle la charge est à la fois transférée par le radier et les micropieux. Cependant, il n’existe actuellement aucune norme en matière de conception de fondations sur MPR ni de données sur leurs performances. Dans la présente étude, des essais géotechniques en centrifugeuse ont été réalisés pour étudier le comportement de fondations sur MPR construites dans l’argile et évaluer leurs paramètres de performance. Dans cette étude, on a évalué les performances des MPR par rapport à celles d’un radier, en examinant le tassement total et différentiel du radier, la pression de contact exercée sur le radier, le moment de flexion dans le radier et la répartition de la charge entre le radier et les micropieux. Les résultats ont montré que, dans la configuration MPR choisie ici, le radier supportait 48 % de la charge appliquée sur l’ensemble de la structure de fondation. On a également constaté que la méthode de Poulos–Davis–Randolph (PDR) pouvait servir à évaluer, avec une marge d’erreur d’environ 17 %, les performances d’une fondation sur MPR lors de l’étape de conception préliminaire. [Traduit par la Rédaction]
Performance of micropiled raft in clay subjected to vertical concentrated load: centrifuge modeling
Alnuaim, A.M (Autor:in) / El Naggar, M.H / El Naggar, H
2015
Aufsatz (Zeitschrift)
Englisch
clay , radier sur micropieux , Models , Clay , centrifugeuse , répartition de la charge , Engineering models , micropiled raft , Usage , Geotechnology , Centrifugal force , Soil mechanics , axial stiffness , Piling (Civil engineering) , Centrifuges , settlement , centrifuge , Mechanical properties , argile , rigidité axiale , load sharing , Load , tassement
Performance of micropiled raft in sand subjected to vertical concentrated load: centrifuge modeling
British Library Online Contents | 2015
|Performance of micropiled raft in clay subjected to vertical concentrated load: centrifuge modeling
British Library Online Contents | 2015
|Performance of micropiled raft in sand subjected to vertical concentrated load: centrifuge modeling
Online Contents | 2015
|Bearing capacity of micropiled-raft system
British Library Online Contents | 2017
|Performance of micropiled rafts in clay: Numerical investigation
British Library Online Contents | 2018
|