Analysis and strengthening of caisson foundations for uplift loads
Many existing self-supporting towers are built with constant-width caisson foundations. Due to the increased demand to add more antennas to the towers, and more stringent strength requirements in recently revised design standards, many existing caisson foundations require significant strengthening for additional uplift resistance. Although a number of retrofit design solutions are frequently used in practice, there is a lack of literature providing guidelines for the proper analysis of retrofitted foundations. This study proposes a detailed analysis and design methodology to significantly increase the uplift capacity of existing caissons through the use of helical micro piles and reinforced concrete cap beams. Strut-and-tie models are developed and nonlinear finite element analyses are undertaken to verify the behaviour of the proposed design. The overall design methodology is presented in a case study involving an existing tower. The proposed design has a general applicability and is suitable for applications where there is limited space around the existing foundations.
Un grand nombre de tours autoportantes existantes sont construites avec des fondations sur puits bétonnés de largeur constante. En raison de la demande accrue pour ajouter plus d’antennes aux tours et des exigences de résistance plus rigoureuses suite à la récente révision des normes de conception, un grand nombre de fondations sur puits bétonnés existantes requièrent une importante consolidation en vue d’augmenter la résistance au soulèvement. Bien qu’on utilise fréquemment un certain nombre de solutions de conception adapté, il y peu de littérature qui donne des directives pour bien analyser les fondations adaptées. Cette étude propose une analyse détaillée et une méthodologie de conception en vue de considérablement augmenter la capacité de résistance au soulèvement des puits bétonnés au moyen de micropieux hélicoïdes et de poutres à tête en béton armé. On développe des modèles à treillis et on fait des analyses par éléments finis non linéaires afin de vérifier le comportement de la conception proposée. On présente la méthodologie de conception générale au moyen d’une étude de cas impliquant une tour existante. La conception proposée a une applicabilité générale et convient dans le cas d’applications où il y a un espace restreint autour des fondations existantes. [Traduit par la Rédaction]
Analysis and strengthening of caisson foundations for uplift loads
Many existing self-supporting towers are built with constant-width caisson foundations. Due to the increased demand to add more antennas to the towers, and more stringent strength requirements in recently revised design standards, many existing caisson foundations require significant strengthening for additional uplift resistance. Although a number of retrofit design solutions are frequently used in practice, there is a lack of literature providing guidelines for the proper analysis of retrofitted foundations. This study proposes a detailed analysis and design methodology to significantly increase the uplift capacity of existing caissons through the use of helical micro piles and reinforced concrete cap beams. Strut-and-tie models are developed and nonlinear finite element analyses are undertaken to verify the behaviour of the proposed design. The overall design methodology is presented in a case study involving an existing tower. The proposed design has a general applicability and is suitable for applications where there is limited space around the existing foundations.
Un grand nombre de tours autoportantes existantes sont construites avec des fondations sur puits bétonnés de largeur constante. En raison de la demande accrue pour ajouter plus d’antennes aux tours et des exigences de résistance plus rigoureuses suite à la récente révision des normes de conception, un grand nombre de fondations sur puits bétonnés existantes requièrent une importante consolidation en vue d’augmenter la résistance au soulèvement. Bien qu’on utilise fréquemment un certain nombre de solutions de conception adapté, il y peu de littérature qui donne des directives pour bien analyser les fondations adaptées. Cette étude propose une analyse détaillée et une méthodologie de conception en vue de considérablement augmenter la capacité de résistance au soulèvement des puits bétonnés au moyen de micropieux hélicoïdes et de poutres à tête en béton armé. On développe des modèles à treillis et on fait des analyses par éléments finis non linéaires afin de vérifier le comportement de la conception proposée. On présente la méthodologie de conception générale au moyen d’une étude de cas impliquant une tour existante. La conception proposée a une applicabilité générale et convient dans le cas d’applications où il y a un espace restreint autour des fondations existantes. [Traduit par la Rédaction]
Analysis and strengthening of caisson foundations for uplift loads
Guner, Serhan (Autor:in) / Carrière, Jean