Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Accuracy of single-jet water meters during filling of the pipe network in intermittent water supply
In intermittently operated water distribution systems the air intruded into the pipe network through the filling and emptying process must inevitably exit the system at some point. Part of this air is discharged through service connections and thus through water meters. Due to this air flow, water meters are being used contrary to their actual conception. This article presents a study in which the measurement error of single-jet water meters due to the filling process of an empty service connection is experimentally examined. It shows that this error is caused mainly by the air flow before the water front reaches the water meter. The correlation between the measurement error and the air volume in front of the water meter is almost linear. The impact of the water front, the presence of water-air mixtures or unsteady flow processes however, is shown to have very little influence on the results.
Accuracy of single-jet water meters during filling of the pipe network in intermittent water supply
In intermittently operated water distribution systems the air intruded into the pipe network through the filling and emptying process must inevitably exit the system at some point. Part of this air is discharged through service connections and thus through water meters. Due to this air flow, water meters are being used contrary to their actual conception. This article presents a study in which the measurement error of single-jet water meters due to the filling process of an empty service connection is experimentally examined. It shows that this error is caused mainly by the air flow before the water front reaches the water meter. The correlation between the measurement error and the air volume in front of the water meter is almost linear. The impact of the water front, the presence of water-air mixtures or unsteady flow processes however, is shown to have very little influence on the results.
Accuracy of single-jet water meters during filling of the pipe network in intermittent water supply
Walter, David (Autor:in) / Mastaller, Miran / Klingel, Philipp
Urban water journal ; 14
2017
Aufsatz (Zeitschrift)
Englisch
Pipe , Water distribution systems , Water engineering , Air , Measuring instruments , Emptying , Correlation analysis , Water , Air flow , pipe filling process , Water supply , water meter , water meter accuracy , Error analysis , Intermittent water supply , Measurement , Unsteady flow , Water distribution , air flow , Automatic meter reading
Accuracy of single-jet water meters during filling of the pipe network in intermittent water supply
Taylor & Francis Verlag | 2017
|Modeling of distribution network filling process during intermittent supply
British Library Conference Proceedings | 2010
|Air entrapment modelling in water supply networks during pipe filling events
Taylor & Francis Verlag | 2024
|The accuracy and durability of water meters
Engineering Index Backfile | 1899
|