Correcting indirect strain measurements in laboratory uniaxial compressive testing at various scales
Abstract Various devices can directly or indirectly measure strain and record the deformational response of rock materials in uniaxial compressive strength tests. Strain gauges glued to specimens directly measure electrical resistance, while displacement sensors, typically linear variable differential transformers (LVDTs), indirectly measure linear displacements. However, no guidance is available regarding how to position the LVDTs to accurately measure axial or radial strain. A common practice is to measure axial strain with displacement sensors on the basis of the reduction in span between steel platens in relation to specimen height. If the deformational response for axial strain measured using strain gauges and displacement sensors is compared, however, it may be that neither maximum axial strain nor elastic constants are the same. This paper describes an approach to correcting platen-to-platen displacement measurements based on energy calculations at different scales in Olkiluoto gneissic rock specimens, with control specimens tested by combining strain gauge and displacement sensor measurements. It is suggested that the approach may be adaptable to other rocks.
Correcting indirect strain measurements in laboratory uniaxial compressive testing at various scales
Abstract Various devices can directly or indirectly measure strain and record the deformational response of rock materials in uniaxial compressive strength tests. Strain gauges glued to specimens directly measure electrical resistance, while displacement sensors, typically linear variable differential transformers (LVDTs), indirectly measure linear displacements. However, no guidance is available regarding how to position the LVDTs to accurately measure axial or radial strain. A common practice is to measure axial strain with displacement sensors on the basis of the reduction in span between steel platens in relation to specimen height. If the deformational response for axial strain measured using strain gauges and displacement sensors is compared, however, it may be that neither maximum axial strain nor elastic constants are the same. This paper describes an approach to correcting platen-to-platen displacement measurements based on energy calculations at different scales in Olkiluoto gneissic rock specimens, with control specimens tested by combining strain gauge and displacement sensor measurements. It is suggested that the approach may be adaptable to other rocks.
Correcting indirect strain measurements in laboratory uniaxial compressive testing at various scales
Alejano, Leandro R. (Autor:in) / Arzúa, Javier (Autor:in) / Estévez-Ventosa, Xián (Autor:in) / Suikkanen, Johannes (Autor:in)
2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
BKL:
56.00$jBauwesen: Allgemeines
/
38.58
Geomechanik
/
38.58$jGeomechanik
/
56.20
Ingenieurgeologie, Bodenmechanik
/
56.00
Bauwesen: Allgemeines
/
56.20$jIngenieurgeologie$jBodenmechanik
RVK:
ELIB18
Compressive Uniaxial and Triaxial Testing of Asphaltic Mixtures
British Library Conference Proceedings | 2006
|Uniaxial Compressive Behavior of Granite at High Strain Rates
Online Contents | 2021
|FEM-DEM simulation of Uniaxial Compressive Strength (UCS) laboratory tests
DOAJ | 2020
|