Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Energy retrofit using vacuum insulation panels: An alternative solution for enhancing the thermal performance of wood-frame walls
Field monitorings of thermal performance of residential 2 x 6 wood-frame wall systems that had been retrofitted using vacuum insulation panels (VIPs) and extruded polystyrene foam (XPS) panels were undertaken in May 2011 – May 2012 at the Field Exposure of Walls Facility (FEWF) of NRC-Construction. The main objective of this research was to measure the steady-state and transient thermal performance of three wall assemblies (4 ft x 6 ft), two of which incorporated VIPs within an XPS Tongue and Groove (T&G) configuration and VIPs within an XPS Clip-On (C-O) configuration, and a third assembly incorporating only XPS. The three wall assemblies were installed in the FEWF for 1-year cycle of exposure to outdoor natural weather conditions. The hygIRC-C model was used in this study. The results of the model calculations were in good agreement with the experimental data. Given that the VIPs could be punctured during the installation process or could fail during normal operating conditions, additional model calculations were used to predict the thermal resistance in cases where one or more VIPs failed. The model was also used to predict the yearly cumulative heat losses across these wall systems. It is important to point out that the aging effect and the effect of the thermal bridging due to envelope (i.e. skin) of the VIPs are not accounted for in this study. However, sensitivity analysis of the thickness and thermal conductivity of the VIP envelope was conducted to investigate the effect of these parameters on the effective thermal resistance of VIP.
Energy retrofit using vacuum insulation panels: An alternative solution for enhancing the thermal performance of wood-frame walls
Field monitorings of thermal performance of residential 2 x 6 wood-frame wall systems that had been retrofitted using vacuum insulation panels (VIPs) and extruded polystyrene foam (XPS) panels were undertaken in May 2011 – May 2012 at the Field Exposure of Walls Facility (FEWF) of NRC-Construction. The main objective of this research was to measure the steady-state and transient thermal performance of three wall assemblies (4 ft x 6 ft), two of which incorporated VIPs within an XPS Tongue and Groove (T&G) configuration and VIPs within an XPS Clip-On (C-O) configuration, and a third assembly incorporating only XPS. The three wall assemblies were installed in the FEWF for 1-year cycle of exposure to outdoor natural weather conditions. The hygIRC-C model was used in this study. The results of the model calculations were in good agreement with the experimental data. Given that the VIPs could be punctured during the installation process or could fail during normal operating conditions, additional model calculations were used to predict the thermal resistance in cases where one or more VIPs failed. The model was also used to predict the yearly cumulative heat losses across these wall systems. It is important to point out that the aging effect and the effect of the thermal bridging due to envelope (i.e. skin) of the VIPs are not accounted for in this study. However, sensitivity analysis of the thickness and thermal conductivity of the VIP envelope was conducted to investigate the effect of these parameters on the effective thermal resistance of VIP.
Energy retrofit using vacuum insulation panels: An alternative solution for enhancing the thermal performance of wood-frame walls
Saber, Hamed H (Autor:in) / Maref, Wahid (Autor:in) / Gnanamurugan, Ganapathy (Autor:in) / Nicholls, Mike (Autor:in)
Journal of Building Physics ; 39 ; 35-68
01.07.2015
34 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Vacuum insulation panels in wood frame wall constructions with different stud profiles
SAGE Publications | 2012
|