Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Measurement of indoor radon, thoron and their progeny levels in dwellings of Union Territory Chandigarh, India: correlation with radon exhalation rates
Presence of radon, thoron and their decay products in household environment is considered a potential health hazard. Measurement of their levels is an important aspect to assess the threat they may pose to humans. Considering this their measurement from some dwellings of Union Territory Chandigarh, India has been carried out. Seasonal variation of these values has also been studied. A correlation study of exhalation rates from soil samples of areas close to the dwellings has also been carried out. The indoor radon concentration varied from 7.9 ± 0.5 to 39.2 ± 2.3 Bq m−3 with an average of 23.3 Bq m−3 while the thoron concentration in the same dwellings varied from 0.15 ± 0.01 to 24.6 ± 1.0 Bq m−3 with an average of 10.7 Bq m−3. Annual effective dose varied from 0.3 to 1.4 mSv with an average of 0.8 mSv. The radon mass and surface exhalation rates from the soil samples varied from 0.9 to 1.9 mBq/kg/h with an average of 1.39 ± 0.29 mBq/kg/h and 20.7–42.3 mBq/m2/h with an average of 31.4 ± 6.8 mBq/m2/h, respectively. The value of in situ gamma dose found to be varied from 0.14 to 0.31 µSv/h.
Measurement of indoor radon, thoron and their progeny levels in dwellings of Union Territory Chandigarh, India: correlation with radon exhalation rates
Presence of radon, thoron and their decay products in household environment is considered a potential health hazard. Measurement of their levels is an important aspect to assess the threat they may pose to humans. Considering this their measurement from some dwellings of Union Territory Chandigarh, India has been carried out. Seasonal variation of these values has also been studied. A correlation study of exhalation rates from soil samples of areas close to the dwellings has also been carried out. The indoor radon concentration varied from 7.9 ± 0.5 to 39.2 ± 2.3 Bq m−3 with an average of 23.3 Bq m−3 while the thoron concentration in the same dwellings varied from 0.15 ± 0.01 to 24.6 ± 1.0 Bq m−3 with an average of 10.7 Bq m−3. Annual effective dose varied from 0.3 to 1.4 mSv with an average of 0.8 mSv. The radon mass and surface exhalation rates from the soil samples varied from 0.9 to 1.9 mBq/kg/h with an average of 1.39 ± 0.29 mBq/kg/h and 20.7–42.3 mBq/m2/h with an average of 31.4 ± 6.8 mBq/m2/h, respectively. The value of in situ gamma dose found to be varied from 0.14 to 0.31 µSv/h.
Measurement of indoor radon, thoron and their progeny levels in dwellings of Union Territory Chandigarh, India: correlation with radon exhalation rates
Mehta, V. (Autor:in) / Kumar, A. (Autor:in) / Singh, S. P. (Autor:in) / Chauhan, R. P. (Autor:in) / Mudahar, G. S. (Autor:in)
Indoor and Built Environment ; 24 ; 833-842
01.10.2015
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
SAGE Publications | 2016
|Seasonal variation of indoor radon–thoron levels in dwellings of four districts of Haryana, India
Taylor & Francis Verlag | 2019
|Indoor Radon-Thoron Levels in Dwellings of the Hilly Regions Surrounding Guwahati, Assam
Online Contents | 2003
|