Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Life-cycle cost evaluation of steel structures retrofitted with steel slit damper and shape memory alloy–based hybrid damper
In this study, the seismic capacity of a hybrid damper, composed of a steel slit plate damper and two shape memory alloy bars, is investigated through fragility analysis and life-cycle cost evaluation of a steel frame retrofitted with the damper. The nonlinear time history analysis model frames show that the seismic responses of the frames equipped with hybrid damper are significantly lesser than the frames retrofitted with conventional slit dampers. The enhancement in the seismic performance of frames retrofitted with hybrid damper is because of extra stiffness, energy dissipation, and self-centering capability provided by the shape memory alloy bars. It is also observed that the life-cycle cost of the frames equipped with hybrid dampers is smallest compared with the life-cycle cost of the bare frames and the frames equipped with slit dampers, even though the initial cost is of the hybrid damper is higher than that of the conventional slit damper.
Life-cycle cost evaluation of steel structures retrofitted with steel slit damper and shape memory alloy–based hybrid damper
In this study, the seismic capacity of a hybrid damper, composed of a steel slit plate damper and two shape memory alloy bars, is investigated through fragility analysis and life-cycle cost evaluation of a steel frame retrofitted with the damper. The nonlinear time history analysis model frames show that the seismic responses of the frames equipped with hybrid damper are significantly lesser than the frames retrofitted with conventional slit dampers. The enhancement in the seismic performance of frames retrofitted with hybrid damper is because of extra stiffness, energy dissipation, and self-centering capability provided by the shape memory alloy bars. It is also observed that the life-cycle cost of the frames equipped with hybrid dampers is smallest compared with the life-cycle cost of the bare frames and the frames equipped with slit dampers, even though the initial cost is of the hybrid damper is higher than that of the conventional slit damper.
Life-cycle cost evaluation of steel structures retrofitted with steel slit damper and shape memory alloy–based hybrid damper
NourEldin, Mohamed (Autor:in) / Naeem, Asad (Autor:in) / Kim, Jinkoo (Autor:in)
Advances in Structural Engineering ; 22 ; 3-16
01.01.2019
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
COMPLEX DAMPER COMBINED WITH STEEL SLIT DAMPER AND VISCOELASTIC DAMPER
Europäisches Patentamt | 2018
|COMPLEX DAMPER COMBINED WITH STEEL SLIT DAMPER AND VISCOELASTIC DAMPER
Europäisches Patentamt | 2019