Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
A test programme was carried out to investigate the performance of 27 axially loaded column specimens, including 18 steel tubes infilled with ultra-high strength concrete (UHSC) of compressive strength close to 200 MPa, 4 steel tubes infilled with normal strength concrete (NSC) and 5 hollow steel tubes. Steel fibres were added into the UHSC to study their effect in enhancing the ductility and strength. Concrete filled double-tube columns were also investigated for potential application in multi-storey and high-rise constructions. Test results showed that UHSC filled tubular columns achieved ultra-high load-carrying capacities, but they could become brittle after the maximum load was attained. In addition, the ductility and strength of composite columns infilled with UHSC was improved by applying load only on the concrete core, adding steel fibres into the concrete core or increasing the steel contribution ratio. Comparison of test results with Eurocode 4's predictions indicates that the Eurocode 4 method could be safely extended to predict the compressive resistance of UHSC filled composite stub columns. On average, Eurocode 4 approach underestimated the resistance by 14.6% if the confinement effect was not considered and by 3.5% if the confinement effect was considered for all the specimens involving UHSC. However, to ensure sufficient ductility, it is recommended that a minimum steel contribution ratio of 0.30 or 1% steel fibres should be used. Furthermore, strength enhancement due to confinement effect should be ignored in estimating the ultimate strength of concrete filled composite columns with Class 3 steel sections.
Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
A test programme was carried out to investigate the performance of 27 axially loaded column specimens, including 18 steel tubes infilled with ultra-high strength concrete (UHSC) of compressive strength close to 200 MPa, 4 steel tubes infilled with normal strength concrete (NSC) and 5 hollow steel tubes. Steel fibres were added into the UHSC to study their effect in enhancing the ductility and strength. Concrete filled double-tube columns were also investigated for potential application in multi-storey and high-rise constructions. Test results showed that UHSC filled tubular columns achieved ultra-high load-carrying capacities, but they could become brittle after the maximum load was attained. In addition, the ductility and strength of composite columns infilled with UHSC was improved by applying load only on the concrete core, adding steel fibres into the concrete core or increasing the steel contribution ratio. Comparison of test results with Eurocode 4's predictions indicates that the Eurocode 4 method could be safely extended to predict the compressive resistance of UHSC filled composite stub columns. On average, Eurocode 4 approach underestimated the resistance by 14.6% if the confinement effect was not considered and by 3.5% if the confinement effect was considered for all the specimens involving UHSC. However, to ensure sufficient ductility, it is recommended that a minimum steel contribution ratio of 0.30 or 1% steel fibres should be used. Furthermore, strength enhancement due to confinement effect should be ignored in estimating the ultimate strength of concrete filled composite columns with Class 3 steel sections.
Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
Liew, J.Y. Richard (Autor:in) / Xiong, D.X. (Autor:in)
Advances in Structural Engineering ; 15 ; 1487-1503
01.09.2012
17 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
Online Contents | 2012
|Tubular columns boost multi-storey construction
British Library Online Contents | 2000
Multi-Storey construction in concrete
Engineering Index Backfile | 1958
|Multi-storey construction in concrete
Engineering Index Backfile | 1958
|Circular double-tube concrete-filled tubular columns with ultra-high strength concrete
British Library Conference Proceedings | 2015
|