Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes
The passive electromagnetic damper was commonly simplified into the linear viscous model in numerical analysis, while this simplification may produce large error when the damper inductance is obvious. In this article, an optimal passive electromagnetic damper with good performance and economy characteristic is proposed by parameter optimization, where the damping density is set as the optimization objective. The hysteresis behavior of the passive electromagnetic damper is verified, and by neglecting the inductance effect, the passive electromagnetic damper can be simplified into the linear viscous model in some cases, but actually the inductance effect is obvious under the high-frequency excitation. Subsequently, the effect of inductance on seismic performance of building damper system under the near-fault earthquake is investigated by comparing the simplified linear viscous model and the accurate passive electromagnetic model. The passive electromagnetic damper was supplemented in a 9-story building, and the analysis of the accurate passive electromagnetic model was carried out by the co-simulation of MATLAB and OpenSees based on the client–server technology. It concludes that the inductance effect is obvious and causes large error when the building damper system is subjected to the near-fault earthquake, and the energy dissipation performance described by the linear viscous model is overestimated.
Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes
The passive electromagnetic damper was commonly simplified into the linear viscous model in numerical analysis, while this simplification may produce large error when the damper inductance is obvious. In this article, an optimal passive electromagnetic damper with good performance and economy characteristic is proposed by parameter optimization, where the damping density is set as the optimization objective. The hysteresis behavior of the passive electromagnetic damper is verified, and by neglecting the inductance effect, the passive electromagnetic damper can be simplified into the linear viscous model in some cases, but actually the inductance effect is obvious under the high-frequency excitation. Subsequently, the effect of inductance on seismic performance of building damper system under the near-fault earthquake is investigated by comparing the simplified linear viscous model and the accurate passive electromagnetic model. The passive electromagnetic damper was supplemented in a 9-story building, and the analysis of the accurate passive electromagnetic model was carried out by the co-simulation of MATLAB and OpenSees based on the client–server technology. It concludes that the inductance effect is obvious and causes large error when the building damper system is subjected to the near-fault earthquake, and the energy dissipation performance described by the linear viscous model is overestimated.
Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes
Guo, Wei (Autor:in) / Wu, Xiaoli (Autor:in) / Wei, Xinna (Autor:in) / Cui, Yao (Autor:in) / Bu, Dan (Autor:in)
Advances in Structural Engineering ; 23 ; 320-333
01.01.2020
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Performance of Structures with Passive Dampers Subject to Near-Fault Earthquakes
British Library Conference Proceedings | 2002
|Taylor & Francis Verlag | 2022
|Response of Structures with Viscous Dampers Subjected to Large Earthquakes
British Library Conference Proceedings | 2013
|