Experimental study on punching shear behavior of hollow floor slab-column reinforced connection
This article presents an experimental study on hollow floor slab-column-reinforced connections, which are enhanced by installing locally solid zone of slab around the column and hidden beam in the floor. To investigate the punching-shear behavior of hollow floor slab-column-reinforced connections, six hollow floor slab-column-reinforced connections under vertical load were conducted on three types of connections with different thickness, namely, two hollow floor slab-column-reinforced connections without punching component, two hollow floor slab-column-reinforced connections with bent-up steel bars, and two hollow floor slab-column-reinforced connections with welding section steel cross bridging. Meanwhile, the strength, stiffness, failure mode, and ductility of hollow floor slab-column-reinforced connections with punching components were obtained and compared with the hollow floor slab-column-reinforced connections without punching component. The results showed that hollow floor slab-column-reinforced connections had the double failure characteristics including punching shear and flexural failure, and flexural failure was the main failure mode as a result of installing hidden beam. The hollow floor slab-column-reinforced connections with punching components exhibited higher initial stiffness and higher loading capacity than hollow floor slab-column-reinforced connections without punching components, but welding section steel cross bridging have a better on improving the connections’ punching-shear capacity than bent-up steel bars.
Experimental study on punching shear behavior of hollow floor slab-column reinforced connection
This article presents an experimental study on hollow floor slab-column-reinforced connections, which are enhanced by installing locally solid zone of slab around the column and hidden beam in the floor. To investigate the punching-shear behavior of hollow floor slab-column-reinforced connections, six hollow floor slab-column-reinforced connections under vertical load were conducted on three types of connections with different thickness, namely, two hollow floor slab-column-reinforced connections without punching component, two hollow floor slab-column-reinforced connections with bent-up steel bars, and two hollow floor slab-column-reinforced connections with welding section steel cross bridging. Meanwhile, the strength, stiffness, failure mode, and ductility of hollow floor slab-column-reinforced connections with punching components were obtained and compared with the hollow floor slab-column-reinforced connections without punching component. The results showed that hollow floor slab-column-reinforced connections had the double failure characteristics including punching shear and flexural failure, and flexural failure was the main failure mode as a result of installing hidden beam. The hollow floor slab-column-reinforced connections with punching components exhibited higher initial stiffness and higher loading capacity than hollow floor slab-column-reinforced connections without punching components, but welding section steel cross bridging have a better on improving the connections’ punching-shear capacity than bent-up steel bars.
Experimental study on punching shear behavior of hollow floor slab-column reinforced connection
Pang, Rui (Autor:in) / Dang, Longji (Autor:in) / Ni, Hongmei (Autor:in) / Liang, Shuting (Autor:in) / Li, Qianqian (Autor:in)
Advances in Structural Engineering ; 22 ; 1531-1543
01.05.2019
13 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DOAJ | 2019
|Springer Verlag | 2019
|Punching Shear Behavior of Reinforced Concrete Hollow Slab
British Library Conference Proceedings | 2008
|Punching shear behaviour analysis of rc flat floor slab-to-column connection
BASE | 2002
|Punching shear behaviour analysis of rc flat floor slab-to-column connection
DOAJ | 2002
|