Inter-personal factors affecting building occupants’ thermal tolerance at cold outdoor condition during an autumn–winter period
The study was conducted to investigate thermal adaptation and the impact of individual differences on developing thermal tolerance when the outdoor temperature falls below 10°C. The applicability of the predicted mean vote (PMV) model was investigated, too. The concept of occupant’s ‘Temperament’ was evaluated as a psychological-adaptation factor. Two main hypotheses were: (a) people with different temperaments would experience different thermal sensations and (b) the classic PMV- predicted percentage dissatisfied (PPD) model is capable of predicting the neutral sensation in heated buildings under cold outdoor temperatures. There was a direct relationship between individual temperament and clothing level as well as thermal sensation. The occupants who were assessed to have cold temperament tend to wear thicker clothes and were more sensitive to variations in indoor air temperature than others. Females with a cold temperament were more than twice as likely to be affected by indoor air temperature as those with a warm temperament. The PMV-PPD model was able to predict the mean neutral temperature in the heated buildings even when the outdoor temperature fell below 10°C. However, when occupants were able to control high indoor temperature, the percentage of true prediction of actual mean votes by the adaptive thermal heat balance model was more than that by the classic PMV model.
Inter-personal factors affecting building occupants’ thermal tolerance at cold outdoor condition during an autumn–winter period
The study was conducted to investigate thermal adaptation and the impact of individual differences on developing thermal tolerance when the outdoor temperature falls below 10°C. The applicability of the predicted mean vote (PMV) model was investigated, too. The concept of occupant’s ‘Temperament’ was evaluated as a psychological-adaptation factor. Two main hypotheses were: (a) people with different temperaments would experience different thermal sensations and (b) the classic PMV- predicted percentage dissatisfied (PPD) model is capable of predicting the neutral sensation in heated buildings under cold outdoor temperatures. There was a direct relationship between individual temperament and clothing level as well as thermal sensation. The occupants who were assessed to have cold temperament tend to wear thicker clothes and were more sensitive to variations in indoor air temperature than others. Females with a cold temperament were more than twice as likely to be affected by indoor air temperature as those with a warm temperament. The PMV-PPD model was able to predict the mean neutral temperature in the heated buildings even when the outdoor temperature fell below 10°C. However, when occupants were able to control high indoor temperature, the percentage of true prediction of actual mean votes by the adaptive thermal heat balance model was more than that by the classic PMV model.
Inter-personal factors affecting building occupants’ thermal tolerance at cold outdoor condition during an autumn–winter period
Ghaffari Jabbari, Shahla (Autor:in) / Maleki, Aida (Autor:in) / Kaynezhad, Mohammad Ali (Autor:in) / Olesen, Bjarne W. (Autor:in)
Indoor and Built Environment ; 29 ; 987-1005
01.08.2020
19 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Winter performance, occupants' comfort and cold stress in prefabricated timber buildings
British Library Online Contents | 2019
|Integrated improvement of occupants' comfort in urban areas during outdoor events
British Library Online Contents | 2015
|Taylor & Francis Verlag | 2007
|