Vibration Tests on a Full-Size Suspen-Dome Structure
A “suspen-dome” structural system consisting of a thin-walled dome and a tensegric system is described, and an overview and results of vibration tests on a full-sized structure are given. The tests revealed the vibration characteristics of the suspen-dome. Close agreement between analytical results based on design information and the test results confirms that the design method used is appropriate. Effectiveness of the suspen-dome against earthquake motions, particularly vertical motions, was confirmed through elastic earthquake response analysis.
Vibration Tests on a Full-Size Suspen-Dome Structure
A “suspen-dome” structural system consisting of a thin-walled dome and a tensegric system is described, and an overview and results of vibration tests on a full-sized structure are given. The tests revealed the vibration characteristics of the suspen-dome. Close agreement between analytical results based on design information and the test results confirms that the design method used is appropriate. Effectiveness of the suspen-dome against earthquake motions, particularly vertical motions, was confirmed through elastic earthquake response analysis.
Vibration Tests on a Full-Size Suspen-Dome Structure
Tatemichi, Ikuo (Autor:in) / Hatato, Tatsuo (Autor:in) / Anma, Yoshimichi (Autor:in) / Fujiwara, Satoshi (Autor:in)
International Journal of Space Structures ; 12 ; 217-224
01.09.1997
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Vibration Tests on a Full-size Suspen-dome Structure
Online Contents | 1997
|Vibration Tests on a Full-size Suspen-dome Structure
British Library Online Contents | 1997
|Structural Tests on a Full-size Suspen-Dome Structure
British Library Conference Proceedings | 1997
|Seismic behaviors of suspen-dome structure
British Library Online Contents | 2005
|Structural Tests of the "Suspen-Dome" System
British Library Conference Proceedings | 1994
|