Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Acoustic emission evaluation of reinforced concrete bridge beam with graphite composite laminate
A test was recently conducted on August 1, 2000 at the FHwA Non-Destructive Evaluation Validation Center, sponsored by The New York State DOT, to evaluate a graphite composite laminate as an effective form of retrofit for reinforced concrete bridge beam. One portion of this testing utilized Acoustic Emission Monitoring for Evaluation of the beam under test. Loading was applied to this beam using a two-point loading scheme at FHwA's facility. This load was applied in several incremental loadings until the failure of the graphite composite laminate took place. Each loading culminated by either visual crack location or large audible emissions from the beam. Between tests external cracks were located visually and highlighted and the graphite epoxy was checked for delamination. Acoustic Emission data was collected to locate cracking areas of the structure during the loading cycles. To collect this Acoustic Emission data, FHwA and NYSDOT utilized a Local Area Monitor, an Acoustic Emission instrument developed in a cooperative effort between FHwA and Physical Acoustics Corporation. Eight Acoustic Emission sensors were attached to the structure, with four on each side, in a symmetrical fashion. As testing progressed and culminated with beam failure, Acoustic Emission data was gathered and correlated against time and test load. This paper will discuss the analysis of this test data.
Acoustic emission evaluation of reinforced concrete bridge beam with graphite composite laminate
A test was recently conducted on August 1, 2000 at the FHwA Non-Destructive Evaluation Validation Center, sponsored by The New York State DOT, to evaluate a graphite composite laminate as an effective form of retrofit for reinforced concrete bridge beam. One portion of this testing utilized Acoustic Emission Monitoring for Evaluation of the beam under test. Loading was applied to this beam using a two-point loading scheme at FHwA's facility. This load was applied in several incremental loadings until the failure of the graphite composite laminate took place. Each loading culminated by either visual crack location or large audible emissions from the beam. Between tests external cracks were located visually and highlighted and the graphite epoxy was checked for delamination. Acoustic Emission data was collected to locate cracking areas of the structure during the loading cycles. To collect this Acoustic Emission data, FHwA and NYSDOT utilized a Local Area Monitor, an Acoustic Emission instrument developed in a cooperative effort between FHwA and Physical Acoustics Corporation. Eight Acoustic Emission sensors were attached to the structure, with four on each side, in a symmetrical fashion. As testing progressed and culminated with beam failure, Acoustic Emission data was gathered and correlated against time and test load. This paper will discuss the analysis of this test data.
Acoustic emission evaluation of reinforced concrete bridge beam with graphite composite laminate
Johnson, Dan E. (Autor:in) / Shen, H. Warren (Autor:in) / Finlayson, Richard D. (Autor:in)
Smart Structures and Materials 2001: Smart Systems for Bridges, Structures, and Highways ; 2001 ; Newport Beach,CA,United States
Proc. SPIE ; 4330
30.07.2001
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Evaluation of damage in reinforced concrete bridge beams using acoustic emission technique
British Library Online Contents | 2012
|Evaluation of Reinforced Concrete Beam Specimens with Acoustic Emission and Cyclic Load Test Methods
Online Contents | 2009
|