An arbitrary waveform neurostimulator for preclinical studies: design and verification
AbstractNeural electrostimulation has enabled different therapies to treat a number of health problems. For example, the cochlear implant allows for recovering the hearing function and deep brain electrostimulation has been proved to reduce tremor in Parkinson’s disease. Other approaches such as retinal prostheses are progressing rapidly, as researchers continue to investigate new strategies to activate targeted neurons more precisely. The use of arbitrary current waveform electrosimulation is a promising technique that allows exploiting the differences that exist among different neural types to enable preferential activation. This work presents a two-channel arbitrary waveform neurostimulator designed for visual prosthetics research. A field programmable gate array (FPGA) was employed to control and generate voltage waveforms via digital-to-analog converters. Voltage waveforms were then electrically isolated and converted to current waveforms using a modified Howland amplifier. Shorting of the electrodes was provided using multiplexers. The FPGA gateware was verified to a high level of confidence using a transaction-level modeled testbench, achieving a line coverage of 91.4%. The complete system was tested in saline using silver electrodes with diameters from 200 to 1000 µm. The bandwidth obtained was 30 kHz with voltage compliance ± 15 V. The neurostimulator can be easily scaled up using the provided in/out trigger ports and adapted to other applications with minor modifications. Graphical Abstract
An arbitrary waveform neurostimulator for preclinical studies: design and verification
AbstractNeural electrostimulation has enabled different therapies to treat a number of health problems. For example, the cochlear implant allows for recovering the hearing function and deep brain electrostimulation has been proved to reduce tremor in Parkinson’s disease. Other approaches such as retinal prostheses are progressing rapidly, as researchers continue to investigate new strategies to activate targeted neurons more precisely. The use of arbitrary current waveform electrosimulation is a promising technique that allows exploiting the differences that exist among different neural types to enable preferential activation. This work presents a two-channel arbitrary waveform neurostimulator designed for visual prosthetics research. A field programmable gate array (FPGA) was employed to control and generate voltage waveforms via digital-to-analog converters. Voltage waveforms were then electrically isolated and converted to current waveforms using a modified Howland amplifier. Shorting of the electrodes was provided using multiplexers. The FPGA gateware was verified to a high level of confidence using a transaction-level modeled testbench, achieving a line coverage of 91.4%. The complete system was tested in saline using silver electrodes with diameters from 200 to 1000 µm. The bandwidth obtained was 30 kHz with voltage compliance ± 15 V. The neurostimulator can be easily scaled up using the provided in/out trigger ports and adapted to other applications with minor modifications. Graphical Abstract
An arbitrary waveform neurostimulator for preclinical studies: design and verification
Med Biol Eng Comput
Guzman-Miranda, Hipolito (Autor:in) / Barriga-Rivera, Alejandro (Autor:in)
12.12.2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Arbitrary waveform generator applied to simulation - Information from Comtest
British Library Online Contents | 2010
Blobitecture : waveform architecture and digital design
UB Braunschweig | 2003
|Blobitecture : waveform architecture and organic design
TIBKAT | 2003
|Mutual Information Model of Adaptive Waveform Design
British Library Online Contents | 2011
|