Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Evaluating the Residual Capacity of Reinforced Concrete Column After Standard Fire Exposure
This paper presents an approach to evaluating the post-fire residual capacity of reinforced concrete columns by finite element analysis. Initially developed FE model was validated against an experimental test result. The analysis was performed in two stages: first, fire exposure through thermal response; then, after cooling down, the structural response of the fire-affected specimen to determine the residual capacity. Three different RC square columns with different reinforcement percentages (1, 2, and 3%) were analyzed. Each of these columns was exposed to a standard fire for 60 to 240 min. The outcome from this analysis shows that RC column residual capacity and stiffness decrease as fire exposure duration increases. The results show that for the first 60 min of fire exposure, the residual capacities of all RC columns were 56–68% of their nominal capacities. Among the three column sections, it was observed that the residual capacity degraded faster in cases of columns with smaller cross-section. The residual capacity obtained from FE analysis was finally compared with that calculated using simplified method. From the comparison it was found that, simplified method’s prediction of after fire residual capacities were nonconservative for the RC columns exposed in fire for shorter duration.
Evaluating the Residual Capacity of Reinforced Concrete Column After Standard Fire Exposure
This paper presents an approach to evaluating the post-fire residual capacity of reinforced concrete columns by finite element analysis. Initially developed FE model was validated against an experimental test result. The analysis was performed in two stages: first, fire exposure through thermal response; then, after cooling down, the structural response of the fire-affected specimen to determine the residual capacity. Three different RC square columns with different reinforcement percentages (1, 2, and 3%) were analyzed. Each of these columns was exposed to a standard fire for 60 to 240 min. The outcome from this analysis shows that RC column residual capacity and stiffness decrease as fire exposure duration increases. The results show that for the first 60 min of fire exposure, the residual capacities of all RC columns were 56–68% of their nominal capacities. Among the three column sections, it was observed that the residual capacity degraded faster in cases of columns with smaller cross-section. The residual capacity obtained from FE analysis was finally compared with that calculated using simplified method. From the comparison it was found that, simplified method’s prediction of after fire residual capacities were nonconservative for the RC columns exposed in fire for shorter duration.
Evaluating the Residual Capacity of Reinforced Concrete Column After Standard Fire Exposure
Lecture Notes in Civil Engineering
Alam, M. Shahria (Herausgeber:in) / Hasan, G. M. Jahid (Herausgeber:in) / Billah, A. H. M. Muntasir (Herausgeber:in) / Islam, Kamrul (Herausgeber:in) / Bhuiyan, Md. Mehedi Hassan (Autor:in) / Ahmed, Shameem (Autor:in)
International Conference on Advances in Civil Infrastructure and Construction Materials ; 2023 ; Dhaka, Bangladesh
31.08.2024
9 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Residual Shear Capacity of Reinforced Concrete Beams after Fire Exposure
Springer Verlag | 2020
|Residual Lateral Load Capacity of a High Strength Reinforced Concrete Column After Fire Damage
British Library Conference Proceedings | 2013
|Residual bond strength in steel reinforced concrete columns after fire exposure
British Library Online Contents | 2012
|An approach for evaluating residual capacity of reinforced concrete beams exposed to fire
Online Contents | 2016
|Post-Fire Residual Capacity of Reinforced Concrete Beam
Springer Verlag | 2021
|