Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Research on Vibration Design of Large Compressor Foundation
The safe operation of a compressor machine heavily relies on the proper design of its foundation. The frame-type supporting foundation is usually adopted in engineering. This paper studies the vibration design of the compressor’s foundation. Two types of finite element model for the foundation are considered, which are beam-slab element model and solid element model. By the comparative analysis of vibration mode shape and time-history dynamic calculation, it is concluded that the commonly used beam-slab element model could be unsafe for a design purpose. In contrast, the solid element model is more reliable. Then, the solid element model was used to study the influence of structural arrangement parameters on vibration response, including roof thickness, column’s section size, eccentric unit arrangement and plate cantilever length. It is concluded that the thickness of the top plate has the most significant influence on the vibration response compared to other factors.
Research on Vibration Design of Large Compressor Foundation
The safe operation of a compressor machine heavily relies on the proper design of its foundation. The frame-type supporting foundation is usually adopted in engineering. This paper studies the vibration design of the compressor’s foundation. Two types of finite element model for the foundation are considered, which are beam-slab element model and solid element model. By the comparative analysis of vibration mode shape and time-history dynamic calculation, it is concluded that the commonly used beam-slab element model could be unsafe for a design purpose. In contrast, the solid element model is more reliable. Then, the solid element model was used to study the influence of structural arrangement parameters on vibration response, including roof thickness, column’s section size, eccentric unit arrangement and plate cantilever length. It is concluded that the thickness of the top plate has the most significant influence on the vibration response compared to other factors.
Research on Vibration Design of Large Compressor Foundation
Lecture Notes in Civil Engineering
Yang, Yang (Herausgeber:in) / Qiao, Xiaoshuai (Autor:in) / Sun, Chao (Autor:in) / Hu, Yanzheng (Autor:in) / Jiang, Congbin (Autor:in)
14.02.2023
13 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Vibration Fault Analysis in Screw Compressor and Foundation
British Library Conference Proceedings | 2012
|Large mill foundation vibration isolation method and large mill vibration isolation foundation
Europäisches Patentamt | 2023
|Repair of Foundation for a Large Compressor
British Library Conference Proceedings | 2005
|Foundation health and compressor reliability
Tema Archiv | 1999
|Integral combined foundation for ultra-large vibration table