Experience of Sonic Echo/Impulse Response Testing Difficulties in Timber Piles of Bridge Foundations
Sonic Echo/Impulse response (SE/IR) is an economical nondestructive method to collect information pertaining to the unknown bridge foundations. Studies have shown that factors such as the pile-to-soil stiffness ratio, the length-to-diameter ratio of the pile, the presence of the defects, the anomalies near the pile head, the quality of the sensor attachment, the striking method, and the hammer type affect the success of the SE/IR tests. In the current study, numerous SE/IR tests were performed on three known and unknown bridge foundations and the superiority of the time domain analysis to the frequency domain analysis is concluded as an outcome helping engineers conduct SE/IR tests efficiently. In addition, more affecting factors and difficulties specific to timber foundations are identified and discussed. The results presented in this study shows that factors such as the foundation condition, the environmental conditions, and the improper pile-pile cap attachment can also be the sources of difficulties in determining the depth of timber piles.
Experience of Sonic Echo/Impulse Response Testing Difficulties in Timber Piles of Bridge Foundations
Sonic Echo/Impulse response (SE/IR) is an economical nondestructive method to collect information pertaining to the unknown bridge foundations. Studies have shown that factors such as the pile-to-soil stiffness ratio, the length-to-diameter ratio of the pile, the presence of the defects, the anomalies near the pile head, the quality of the sensor attachment, the striking method, and the hammer type affect the success of the SE/IR tests. In the current study, numerous SE/IR tests were performed on three known and unknown bridge foundations and the superiority of the time domain analysis to the frequency domain analysis is concluded as an outcome helping engineers conduct SE/IR tests efficiently. In addition, more affecting factors and difficulties specific to timber foundations are identified and discussed. The results presented in this study shows that factors such as the foundation condition, the environmental conditions, and the improper pile-pile cap attachment can also be the sources of difficulties in determining the depth of timber piles.
Experience of Sonic Echo/Impulse Response Testing Difficulties in Timber Piles of Bridge Foundations
Lecture Notes in Civil Engineering
Rizzo, Piervincenzo (Herausgeber:in) / Milazzo, Alberto (Herausgeber:in) / Rashidyan, Saman (Autor:in) / Ng, Tang-tat (Autor:in) / Maji, Arup (Autor:in)
European Workshop on Structural Health Monitoring ; 2020
11.01.2021
9 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Testing concrete foundation piles by sonic echo
TIBKAT | 1981
|British Library Online Contents | 2003
|Study of the Effect of Source Application on Sonic Echo Tests in Timber Piles
DOAJ | 2020
|