Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Sensitivity of the Flow to the Inclination of a Single Submerged Groyne in a Curved Flume
Abstract In order to investigate the effect on the flow field due to small changes in the inclination of a single submerged groyne, laboratory tests have been conducted. A double curved S-flume with a length of 26 m, width of 2.4 m and depth of 0.4 m was used. The investigations were done at a reference inclination of 60° for a single submerged groyne. The inclination was then varied by ±5° and ±10°. The groyne width and height as well as the hydraulic conditions (discharge of 130.6 l/s and water depth of 10 cm) were kept constant to ensure that the effect is only due to the change in the inclination. The groyne was installed in the first cross-section of the first curve. The 3D flow field was measured using a Nortek Vectrino Plus in nine cross-sections with seven vertical profiles each. The total flow measurement points were 325 in each run. The results of the experiments have shown no significant changes in the flow field due to the change of inclination up to ±10° given that the projected length and the hydraulic boundary conditions were kept constant. However, localized effects at cross-section no 1 are evident and the inclination of 60° showed the lowest stream-wise velocity. Comparison of the flow field with and without groyne revealed decreasing velocities at the outer bank and increasing velocities at the inner bank supporting the purpose of the structure which is bank protection.
Sensitivity of the Flow to the Inclination of a Single Submerged Groyne in a Curved Flume
Abstract In order to investigate the effect on the flow field due to small changes in the inclination of a single submerged groyne, laboratory tests have been conducted. A double curved S-flume with a length of 26 m, width of 2.4 m and depth of 0.4 m was used. The investigations were done at a reference inclination of 60° for a single submerged groyne. The inclination was then varied by ±5° and ±10°. The groyne width and height as well as the hydraulic conditions (discharge of 130.6 l/s and water depth of 10 cm) were kept constant to ensure that the effect is only due to the change in the inclination. The groyne was installed in the first cross-section of the first curve. The 3D flow field was measured using a Nortek Vectrino Plus in nine cross-sections with seven vertical profiles each. The total flow measurement points were 325 in each run. The results of the experiments have shown no significant changes in the flow field due to the change of inclination up to ±10° given that the projected length and the hydraulic boundary conditions were kept constant. However, localized effects at cross-section no 1 are evident and the inclination of 60° showed the lowest stream-wise velocity. Comparison of the flow field with and without groyne revealed decreasing velocities at the outer bank and increasing velocities at the inner bank supporting the purpose of the structure which is bank protection.
Sensitivity of the Flow to the Inclination of a Single Submerged Groyne in a Curved Flume
Zaid, Bahaeldeen A. (Autor:in) / Koll, Katinka (Autor:in)
01.01.2016
10 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Roughness Effect of Submerged Groyne Fields with Varying Length, Groyne Distance, and Groyne Types
DOAJ | 2019
|Montana Flume Flow Corrections under Submerged Flow
British Library Online Contents | 2012
|Effects of Groyne Layout on the Flow in Groyne Fields: Laboratory Experiments
Online Contents | 2005
|Effects of Groyne Layout on the Flow in Groyne Fields: Laboratory Experiments
British Library Online Contents | 2005
|Engineering Index Backfile | 1954