Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Study on the Influence of Thermal Properties of Building Envelope on Indoor Pollutant Diffusion
At present, China is in a critical period of 70% energy saving in buildings. In order to meet people’s needs for indoor lighting and permeability, the south wall of the same residence in cold region is replaced with the floor-to-ceiling window of Low-E glass in this paper. The realizable k − ε model was used to analyze the influence of outdoor environment conditions on indoor pollutant diffusion process and thermal comfort through different building envelope structure. The results show that the floor-to-ceiling window structure restrains the diffusion of pollutants from the floor at night. After 19 h diffusion, the average concentration value of indoor pollutant in the floor-to-ceiling window structure is 25.7% lower than that of the external wall structure. At this time, the indoor PMV values of the floor-to-ceiling window structure and the external wall structure are 0.14 and 0.05, respectively. And the average indoor temperature of the floor-to-ceiling window structure can meet the requirements of the average indoor temperature of floor heating.
Study on the Influence of Thermal Properties of Building Envelope on Indoor Pollutant Diffusion
At present, China is in a critical period of 70% energy saving in buildings. In order to meet people’s needs for indoor lighting and permeability, the south wall of the same residence in cold region is replaced with the floor-to-ceiling window of Low-E glass in this paper. The realizable k − ε model was used to analyze the influence of outdoor environment conditions on indoor pollutant diffusion process and thermal comfort through different building envelope structure. The results show that the floor-to-ceiling window structure restrains the diffusion of pollutants from the floor at night. After 19 h diffusion, the average concentration value of indoor pollutant in the floor-to-ceiling window structure is 25.7% lower than that of the external wall structure. At this time, the indoor PMV values of the floor-to-ceiling window structure and the external wall structure are 0.14 and 0.05, respectively. And the average indoor temperature of the floor-to-ceiling window structure can meet the requirements of the average indoor temperature of floor heating.
Study on the Influence of Thermal Properties of Building Envelope on Indoor Pollutant Diffusion
Environ Sci Eng
Wang, Zhaojun (Herausgeber:in) / Zhu, Yingxin (Herausgeber:in) / Wang, Fang (Herausgeber:in) / Wang, Peng (Herausgeber:in) / Shen, Chao (Herausgeber:in) / Liu, Jing (Herausgeber:in) / Wang, Ruijun (Autor:in) / Wang, Ye (Autor:in)
The International Symposium on Heating, Ventilation and Air Conditioning ; 2019 ; Harbin, China
Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019) ; Kapitel: 115 ; 1113-1122
15.03.2020
10 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Cold region , Diffusion of pollutants , Air quality Engineering , Building Physics, HVAC , Sustainable Architecture/Green Buildings , Atmospheric Protection/Air Quality Control/Air Pollution , Renewable and Green Energy , Energy Storage , Monitoring/Environmental Analysis , Earth and Environmental Science
Influence of Local Airflow on the Pollutant Emission from Indoor Building Surfaces
Wiley | 2001
|The impact of human-induced turbulence on indoor thermal environment and pollutant diffusion
Springer Verlag | 2025
|The impact of human-induced turbulence on indoor thermal environment and pollutant diffusion
Springer Verlag | 2025
|BUILDING ENVELOPE COMPONENT TO CONTROL THERMAL INDOOR ENVIRONMENT IN SUSTAINABLE BUILDING: A REVIEW
BASE | 2019
|