Comparative Study on Position of Floating Column for RCC Multistorey Building Subjected to Seismic Forces
Nowadays, aesthetic and functional considerations frequently demand irregularity so a Floating column is another sort of irregularity that changes the structure's load pathway. Presence of Floating column in a building is highly dangerous in seismically active areas. In the present study, G + 14 RC building is modeled and analyzed for dynamic loadings using ETABS. The objective of present work is to study the seismic response of building with and without floating column having floating column on different floor levels i.e. at Ground floor, 5th floor, 10th floor and 15th floor. The building with critical position of Floating column is found out and Lateral resisting systems are provided. Results are compared with respect to max storey displacement, storey drift, time period etc. The building is considered to be located in Zone IV with medium soil as per IS1893:2016. The study shows that structure having FC at bottom storey on the outer periphery and at corner of exterior frame is more crucial and seismic performance of building is improved by providing bracings and shear wall.
Comparative Study on Position of Floating Column for RCC Multistorey Building Subjected to Seismic Forces
Nowadays, aesthetic and functional considerations frequently demand irregularity so a Floating column is another sort of irregularity that changes the structure's load pathway. Presence of Floating column in a building is highly dangerous in seismically active areas. In the present study, G + 14 RC building is modeled and analyzed for dynamic loadings using ETABS. The objective of present work is to study the seismic response of building with and without floating column having floating column on different floor levels i.e. at Ground floor, 5th floor, 10th floor and 15th floor. The building with critical position of Floating column is found out and Lateral resisting systems are provided. Results are compared with respect to max storey displacement, storey drift, time period etc. The building is considered to be located in Zone IV with medium soil as per IS1893:2016. The study shows that structure having FC at bottom storey on the outer periphery and at corner of exterior frame is more crucial and seismic performance of building is improved by providing bracings and shear wall.
Comparative Study on Position of Floating Column for RCC Multistorey Building Subjected to Seismic Forces
Lecture Notes in Civil Engineering
Marano, Giuseppe Carlo (Herausgeber:in) / Rahul, A. V. (Herausgeber:in) / Antony, Jiji (Herausgeber:in) / Unni Kartha, G. (Herausgeber:in) / Kavitha, P. E. (Herausgeber:in) / Preethi, M. (Herausgeber:in) / Kakatkar, Varsha (Autor:in) / Jambhale, Nikhil (Autor:in) / Khed, Veerendrakumar C. (Autor:in) / Mendigeri, Shivanand (Autor:in)
International Conference on Structural Engineering and Construction Management ; 2022 ; Angamaly, India
30.10.2022
12 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
Dynamic Response Analysis of Multistorey Masonry Building Subjected to Earthquakes
British Library Conference Proceedings | 1989
|Simplified nonlinear seismic analysis of asymmetric multistorey R/C building
British Library Conference Proceedings | 2002
|Seismic response of multistorey framed shearwalls
Online Contents | 1993
|Romanian code for the design of multistorey steel frames subjected to seismic loads
British Library Conference Proceedings | 1998
|