Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic response characteristics of a base isolated cable-stayed bridge under moderate and strong ground motions
In this study, the seismic behavior of an existing steel cable-stayed bridge equipped with lead-rubber bearing subjected to moderate and strong earthquakes is investigated. The bridge is located at high seismic zone and experienced an earthquake in 1988 which caused the failure of one of its anchorage plate of the support. Herein, the bridge was modeled in three dimensions and the base isolators implemented at the abutments and deck-tower connection. The bridge seismic responses were evaluated through nonlinear dynamic time-history analysis. The comparative analysis confirmed that the base isolation system was an effective tool in reducing seismic force transmit from substructure to superstructure. Furthermore, the overall seismic performance of cable-stayed bridge significantly enhanced in longitudinal and transverse directions. However, it is observed that the axial force of the tower in substructure increased due to the isolation system induced torsional deformation to the superstructure under transverse seismic loads.
Seismic response characteristics of a base isolated cable-stayed bridge under moderate and strong ground motions
In this study, the seismic behavior of an existing steel cable-stayed bridge equipped with lead-rubber bearing subjected to moderate and strong earthquakes is investigated. The bridge is located at high seismic zone and experienced an earthquake in 1988 which caused the failure of one of its anchorage plate of the support. Herein, the bridge was modeled in three dimensions and the base isolators implemented at the abutments and deck-tower connection. The bridge seismic responses were evaluated through nonlinear dynamic time-history analysis. The comparative analysis confirmed that the base isolation system was an effective tool in reducing seismic force transmit from substructure to superstructure. Furthermore, the overall seismic performance of cable-stayed bridge significantly enhanced in longitudinal and transverse directions. However, it is observed that the axial force of the tower in substructure increased due to the isolation system induced torsional deformation to the superstructure under transverse seismic loads.
Seismic response characteristics of a base isolated cable-stayed bridge under moderate and strong ground motions
Archiv.Civ.Mech.Eng
Javanmardi, Ahad (Autor:in) / Ibrahim, Zainah (Autor:in) / Ghaedi, Khaled (Autor:in) / Jameel, Mohammed (Autor:in) / Khatibi, Hamed (Autor:in) / Suhatril, Meldi (Autor:in)
Archives of Civil and Mechanical Engineering ; 17 ; 419-432
01.06.2017
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2017
|British Library Online Contents | 2017
|Seismic response of long span cable-stayed bridge to near-fault vertical ground motions
Springer Verlag | 2014
|Seismic response of long span cable-stayed bridge to near-fault vertical ground motions
Online Contents | 2015
|Earthquake response of isolated cable-stayed bridges under spatially varying ground motions
British Library Online Contents | 2009
|