Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic Behaviour of RC Structure Under Disconnected Piled Raft System
Structures are widely considered to be designed on assuming fixed base condition which is usually limited to hard stratum. The recent evolution lead to initiation on soil structure interaction (SSI) study which is tremendously growing interest in development of huge structures to build on soft soils. Piled raft system is mostly adopted as a foundation system for such highrise building. In this paper, A 12 storey RC structure building is modelled with connected piled raft system and disconnected piled raft system with no structural connection between them where a provision of cushioned layer with granular soil is introduced. By equivalent static method both connected piled raft system and disconnected piled raft system are studied and compared by varied configuration spacing between piles, and cushion thickness are examined by finite element method using Plaxis 3D software. Results showed that the displacement in the structure, inter storey drift, pile displacement on connected and disconnected pile raft system. DPR has performed better when cushion thickness is increased.
Seismic Behaviour of RC Structure Under Disconnected Piled Raft System
Structures are widely considered to be designed on assuming fixed base condition which is usually limited to hard stratum. The recent evolution lead to initiation on soil structure interaction (SSI) study which is tremendously growing interest in development of huge structures to build on soft soils. Piled raft system is mostly adopted as a foundation system for such highrise building. In this paper, A 12 storey RC structure building is modelled with connected piled raft system and disconnected piled raft system with no structural connection between them where a provision of cushioned layer with granular soil is introduced. By equivalent static method both connected piled raft system and disconnected piled raft system are studied and compared by varied configuration spacing between piles, and cushion thickness are examined by finite element method using Plaxis 3D software. Results showed that the displacement in the structure, inter storey drift, pile displacement on connected and disconnected pile raft system. DPR has performed better when cushion thickness is increased.
Seismic Behaviour of RC Structure Under Disconnected Piled Raft System
Lecture Notes in Civil Engineering
Sitharam, T.G. (Herausgeber:in) / Pallepati, Raghuveer Rao (Herausgeber:in) / Kolathayar, Sreevalsa (Herausgeber:in) / Ashok kumar, H. (Autor:in) / Antony, Visuvasam Joseph (Autor:in)
27.03.2021
10 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
British Library Conference Proceedings | 2021
|Settlement-Reducing Effects of Disconnected Piled Raft Foundation System
British Library Conference Proceedings | 2007
|Non-linear soil–structure interaction in disconnected piled raft foundations